SOI/DT 2010-03 dmm
59/78
599 72 84-41
12.1 Temperature
control
The drying temperature is controlled by an NTC sensor positioned on the duct; the heating element casing
features two safety thermostats (one of which is a manual-reset type).
8. Washing heating element
9. PCB
-
WD
10. Safety thermostat (auto-reset)
11. Safety thermostat (manual reset)
12. Drying heating element
13. Fan motor.
14. Drying control NTC sensor
15. Humidity control NTC sensor
27. Main circuit board
1. Drying temperature control
NTC sensor
2. Auto-reset safety thermostat
3. Manual reset safety
thermostat (150°C)
4. Drying heating element
NTC sensor: heating element at
25
°
C
5000
Ω
Manual reset safety thermostat
Normally closed,
opens at 150
°
±5°C
Auto-reset safety thermostat
Normally closed
Opens at 110
°
±3°C
Closes at 94°±5°
Power
920+920 W
Power supply
voltage
230V 240
Heating unit
Resistance
56.5
Ω
+56.5
Ω
61.5
Ω
+61.5
Ω
Fan capacity
approx. 80 m
3
per hour
•
Calculating the drying time:
In the automatic cycles the NTC sensor mounted on the
drying duct is used to calculate the drying time.
1. NTC temperature sensor
2. Tub-condenser
tube
3. Drying
condenser
Содержание TC2
Страница 2: ...SOI DT 2010 03 dmm 2 78 599 72 84 41 ...
Страница 65: ...SOI DT 2010 03 dmm 65 78 599 72 84 41 13 DIAGRAMS 13 1 WM diagram with UNIVERSAL MOTOR EWM 21xx ...
Страница 67: ...SOI DT 2010 03 dmm 67 78 599 72 84 41 13 2 WM diagram with THREE PHASE ASYNCHRONOUS MOTOR EWM 25xx ...
Страница 69: ...SOI DT 2010 03 dmm 69 78 599 72 84 41 13 3 WD diagram with UNIVERSAL MOTOR EWM 21xx ...
Страница 71: ...SOI DT 2010 03 dmm 71 78 599 72 84 41 13 4 WD diagram with THREE PHASE ASYNCHRONOUS MOTOR EWM 25xx ...