SOI/DT 2010-03 dmm
31/78
599 72 84-41
6 DEMO MODE SETTING
Version TC4
Version TC3
“Time Manager” “Proportional”
Version TC2
“Time Manager” “Proportional”
1. Switch off the appliance
2. Press
the
START/PAUSE
button and the nearest
option button
simultaneously (as shown in the figure).
3. Holding down both buttons, switch the appliance on by turning the programme selector
by three
positions clockwise
.
4. Hold the buttons down until
“
dEM
”
flashes for a short time.
6.1 Exiting DEMO mode
To exit demo mode, switch the appliance off (programme selector in off/cancel position)
7 DIAGNOSTIC
SYSTEM
7.1 Accessing
diagnostics
Version TC4
Version TC3
“Time Manager” “Proportional”
Version TC2
“Time Manager” “Proportional”
1. Switch off the appliance
2. Press
the
START/PAUSE
button and the nearest
option button
simultaneously (as shown in the
figure).
3. Holding down both buttons, switch the appliance on by turning the programme selector
by one position
clockwise
.
4. Hold the buttons down until the LEDs and symbols begin to flash in sequence (at least 2 seconds).
In the first position, the operation of the buttons and the related LEDs is checked; turn the programme
selector knob
clockwise
to run the diagnostic cycle for the operation of the various components and to ready
any alarms.
7.2 Quitting the diagnostics system
→
To exit the diagnostic cycle, switch the appliance off, then back on and then off again.
Содержание TC2
Страница 2: ...SOI DT 2010 03 dmm 2 78 599 72 84 41 ...
Страница 65: ...SOI DT 2010 03 dmm 65 78 599 72 84 41 13 DIAGRAMS 13 1 WM diagram with UNIVERSAL MOTOR EWM 21xx ...
Страница 67: ...SOI DT 2010 03 dmm 67 78 599 72 84 41 13 2 WM diagram with THREE PHASE ASYNCHRONOUS MOTOR EWM 25xx ...
Страница 69: ...SOI DT 2010 03 dmm 69 78 599 72 84 41 13 3 WD diagram with UNIVERSAL MOTOR EWM 21xx ...
Страница 71: ...SOI DT 2010 03 dmm 71 78 599 72 84 41 13 4 WD diagram with THREE PHASE ASYNCHRONOUS MOTOR EWM 25xx ...