2 2
CONDENSED WATER
(only applies to condenser tumble dryer)
The machine is supplied with a 2.0 metre-long
drain hose. Use this to remove the condensed
water.
NOTE!
It is important that you use the new rubber
hose that is supplied, not an old hose.
max 1000 mm
1
2
3
VENTING
(only applies to venting tumble dryer)
The exhaust air from the tumble dryer must be
led to a ventilation duct or a wall outlet using
the accompanying vent hose.
Connecting to tumble dryer
The tumble dryer can be vented in three ways:
from the rear, from the right
side or from the left side.
One of the holes is open
when the dryer is delivered.
The other two
are fitted
with covers.
The tumble dryer is supplied
with an adapter (1), a plastic collar (2) and a
vent hose (3).
TUMBLE DRYER
MECHANICAL INSTALLATION
Connect the vent hose as follows:
1
. Slide the vent hose over the end of the adap-
ter and secure with the plastic strap.
2
. Remove the plastic cover from the hole if you
intend to connect the hose to a hole other than
the one that is already open.
3
. Insert the end of the adapter in the hole.
4
. Fit the cover to the open hole.
Connecting to vent duct
The vent hose must follow the shortest, straigh-
test path possible from the tumble dryer to the
vent duct. Cut the vent hose to length if it is
too long. If necessary the vent hose can be ex-
tended to a maximum length of 8 metres (inter-
nal diameter 102 mm). If a longer hose is requi-
red it must have a larger internal diameter in
order to maintain the fan capacity of the dryer.
Any bends should be as gentle as possible. If
it is necessary to make 90º bends there must be
no more than four of them. More bends reduce
the fan capacity of the dryer.
Examples of