Service Manual
11
5.1.2
Heating sensor (PT100)
Description
The heating sensor is placed on the heating module on the back of the machine.
The heating sensor measures the temperature in the inlet air and the signal is returned to the CPU.
The CPU turns the heating unit off when the inlet air thermistor indicates that the required temperature has been
reached.
Replacement of heating sensor (PT100)
Disconnect the power to the machine. Gas heated machine: Shut off the manual gas valve.
Demount the rear panel.
Disconnect the heating sensor and remove it. Connect the new heating sensor and put it in position. Make sure the
sensor gets all the way down.
El and Gas heated machine.
Steam heated machine.
Remount the rear panel.