10
Service Manual
5 Sensors and overheating thermostats
5.1
Inlet air
5.1.1
Overheating thermostat
Description
The inlet overheating thermostat is placed on the heating module on the back of the machine.
The inlet overheating thermostat opens in the event of overheating and shuts off the machine.
Resetting
Disconnect the power to the machine. Gas heated machine: Shut off the manual gas valve.
Demount the rear panel.
Press the reset button (A) on the overheating thermostat.
Note!
Resetting must not be done before the cause for overheating is verified and resolved.
fig.W00252
Remount the rear panel.
Replacement of overheating thermostat
Disconnect the power to the machine. Gas heated machine: Shut off the manual gas valve.
Demount the rear panel.
Disconnect the overheating thermostat and remove it. Connect the new overheating thermostat.
El and Gas heated machine.
Remount the rear panel.
Содержание T5350
Страница 1: ...Service Manual Tumble dryer T5350 Type N2 Original instructions 438 9038 90 EN 2015 11 04 ...
Страница 2: ......
Страница 5: ...Service Manual 5 1 Symbols Caution Caution hot surface Read the instructions before using the machine ...
Страница 14: ...14 Service Manual Remount the rear panel ...
Страница 132: ......
Страница 133: ......