9
Setup
Setup
Unpacking
Unpack the dryer from the packaging.
There are no transportation fittings. Release the
dryer from the pallet by cutting the plastic ribbon..
Positioning
Place the dryer in such a way that work can be
done as easily as possible by the user as well as
the service technician. The door is reversible.
The distance to the wall or other equipment
behind the dryer should be min. 300 mm and the
distance to the sides min. 70 mm (if the dryer is
to be equipped with a coin box the width of the
coin box must also be added). However, for the
purpose of servicing the dryer there should be
free access to the back of it.
The dryer can be positioned on a 55-litre wash-
ing machine to form a washing column.
Mechanical installation
Adjust the dryer to ensure that it is horizontal and
stands firmly on all 4 feet.
The max. height adjustment is 14 mm.
Floor mounting
The dryer can be installed directly on the floor
and fastened by means of the accompanying
cups A.
Fasten the cups by means of the screws.
A drilling plan is given in fig. 3 in the form of
alternative 1 (from the rear) or 2 (from the side),
depending on the space for mounting the rocker
brackets B.
Drill the rawlplug holes using a 10 mm drill.