RETRACTABLE COOKER HOOD
P5
INSTALLATION USING THE SUPPLIED DRAWER FASCIA
FOR MODELS: REHR6* WRH605I* WRH608I* WRH908I*
Standard ducted installation calls for a door extension of 130mm
whether the client opts to use the supplied draw fascia or a custom
fascia of the same dimensions as that supplied.
RECIRCULATING VENT INSTALLATION
Note: If the cooker hood is to be vented using the recirculating vent rather
than standard ducting, the supplied drawer fascia is not to be used
and must be replaced with a client specifi c custom fascia.
The custom drawer fascia must be a minimum of 70mm deep as air
expelled through the recirculating vent must be defl ected upwards.
INSTALLATION INSTRUCTIONS
130
40
3
101
70
3
RECIRCULATE
EXHAUST
Setting of circulation air doors
Unscrew and remove
cover from
recirculating vent
FOR MODELS:
WRH608I* WRH908I
(
WRR614*A
already fitted with 70mm front panel)