Safety Warnings

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or 

mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the 

use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. 

Cleaning and user maintenance shall not be made by children without supervision.

  Ensure the cooker hood is switched off before carrying out maintenance, to avoid any possibility of electric shock.

  Grease 

 lters must be removed every four weeks (maximum) for cleaning to reduce the risk of 

 re.

  Do not 

 ambé under the cooker hood.

  This cooker hood is not recommended for barbeques.

   The exhaust air from the cooker hood must not be discharged into any heating 

 ue, which may carry combustion 

products from other sources.

  Exhaust air must not be discharged into a wall cavity, unless the cavity is designed for the purpose.

   There must be adequate ventilation of the room when the cooker hood is used at the same time as appliances burning 

gas or other fuels.

  Always cover lit gas burners with pots or pans when the cooker hood is in use.

  Always switch off gas burners before you remove pots or pans.

Cleaning

   Wipe the cooker hood body and flue with a sponge or soft cloth soaked in warm soapy water, and dry with a soft cloth,

for stainless steel models apply a stainless steel protector. Do not use oven cleaners or other abrasive materials.

Electrical Connection

  Check that the mains voltage matches with the voltage on the data plate inside the cooker hood.

  Check that the installation complies with standards of local gas and electricity authorities.

   If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly quali

 ed 

person in order to avoid a hazard.

Accessories

  Use 125mm round exhaust ducting for best performance.

  When using 

 exible duct always install duct with the wire helix pulled taut to minimise pressure loss.

  Try to keep exhaust duct short and straight.

  Keep bends in the exhaust duct to a minimum.

  Do not restrict exhaust duct.

13427_Rangehood_Electrolux.indd   2

  CAUTION: Accessible parts may become hot when used with cooking appliance.

  Regulations concerning the discharge of air have to be fulfilled.

there is a fire risk if cleaning is not carried out in accordance with the instructions.

Grease filters must be removed every four weeks (maximum) for cleaning to reduce the risk of fire.

INSTALLATION INSTRUCTIONS

RETRACTABLE COOKER HOOD

P1

Reducing the size of the exhaust duct will reduce the airflow of the cooker hood.

Содержание REHR6 Series

Страница 1: ...ATION INSTRUCTIONS Model REHR6 WRH605I WRH608I WRR614 A WRH908I These cooker hoods are domestic appliances which have been manufactured and tested to comply with Australian and New Zealand Standard AS NZS 60335 2 31 13427_Rangehood_Electrolux indd 1 ...

Страница 2: ...urners before you remove pots or pans Cleaning Wipe the cooker hood body and flue with a sponge or soft cloth soaked in warm soapy water and dry with a soft cloth for stainless steel models apply a stainless steel protector Do not use oven cleaners or other abrasive materials Electrical Connection Check that the mains voltage matches with the voltage on the data plate inside the cooker hood Check ...

Страница 3: ...POINT DIMENSIONS 600mm Retractable cooker hood FIXING POINT DIMENSIONS 900mm Retractable cooker hood INSTALLATION INSTRUCTIONS 600 650 GAS ELECTRIC Ducting hole cover Duct Spigot DUCTING INSTALLATION When installing with ducting pipe the Duct spigot must be fitted to the ducting hole on top of the body of the cooker hood RECIRCULATING INSTALLATION For Models WRH608I WRR614 A WRH908I When installed...

Страница 4: ... be bought through your local appliance retailer or in Australia online at shop electrolux com au RETRACTABLE COOKER HOOD P3 PARTS SUPPLIED WITH HOOD 1 Duct Spigot 1 Ducting hole cover only for WRH608I WRR614 A and WRH908I 4 M6 40 screws 4 φ6 washers 2 Carbon filters only for WRR614 A PARTS TO BE PURCHASED Aluminium tape or cable ties to secure flue pipe Custom drawer fascia if required Ducting ac...

Страница 5: ...upport from upper side STANDARD DUCTED INSTALLATION RETRACTABLE COOKER HOOD P3 2 Fixing duct spigot 1 Drilling holes 3 Fixing the cooker hood 4 Fixing flue pipe to φ7 for hood fastening screws Door hood fascia Front of cabinet 36 drill φ7 hole drill φ45 hole cut φ130 hole 210 470 770 φ clearance hood the duct spigot 200 100 268 φ45 for Cable clearance pulled taut to minimise pressure loss and nois...

Страница 6: ...e cooker hood is to be vented using the recirculating vent rather than standard ducting the supplied drawer fascia is not to be used and must be replaced with a client specific custom fascia The custom drawer fascia must be a minimum of 70mm deep as air expelled through the recirculating vent must be deflected upwards INSTALLATION INSTRUCTIONS 130 40 3 101 70 3 RECIRCULATE EXHAUST Setting of circu...

Страница 7: ...S REHR6 WRH605I WRH608I WRR614 A WRH908I ALL MODELS OPTIONAL CARBON FILTER An optional carbon filter will diminish cooking odours in the recirculated air Depending on the frequency of use and the type of cooking the expected life of carbon filters is from 1 to 6 months Replacement is required Recirculating accessory ARCFD ...

Страница 8: ...y the drawer action see diagram OPERATION MAINTENANCE MAINS SWITCH OFF TO REPLACE LIGHT GLOBES 1 Open drawer and remove filter 2 Turn mains switch off before removing lamp Replace with 28W maximum E14 candle lamp Depending on model will require 1 or 2 globes The lamp assembly includes a silicone seal this must be replaced when a new lamp is used The silicone seal is placed over the lamp thread and...

Страница 9: ...h before cleaning drawer and cooker hood body 5 After cleaning re fit filters making sure the clip pins are securely fitted into the locating holes in the cookerhood body and for twin filter versions also located in the pull out drawer section 6 Holding clip in push opposite side of filter up until pins are over locating holes 7 Release clip ensuring filter is securely fitted Safety Tips Use of tw...

Страница 10: ...misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi incorrect improper or inappropriate operation vii insect or vermin infestation viii failure to comply with any additional instructions supplied with the Appliance b c the Appliance s serial number or wa...

Страница 11: ...NOTES 13427_Rangehood_Electrolux indd 10 ...

Страница 12: ...www electrolux com au www electrolux com nz PLEASE LEAVE THIS BOOKLET WITH THE COOKER HOOD OWNER THANK YOU Version 00 02 Nov 2015 ...

Отзывы: