- 30 -
TSE-N 02.01 A. B.
599 50 93 79 EN
7.3.2 Demo mode
Activating demo mode
1.
Switch on appliance (main switch P8 on)
2.
Press keys P1, P2, P6 and P7 simultaneously
3.
Appliance beeps three times
4.
Demo mode is active
State:
The appliance can be operated in full (without performance). After reset of the main voltage the
demo mode is preserved. After reset of the main voltage the clock starts at 12.00 and does not
flash.
Deactivating demo mode
1.
Switch on appliance (main key P8 on)
2.
Press keys P1, P2, P6 and P7 simultaneously
3.
Appliance beeps three times
4.
Demo mode is not active
State:
The appliance can be operated in full again.
Attention: The demo mode is not valid for the Quattro hot plate control (plate should not be
contacted).
Carrying out the door locking test with Prisma equipment
Equipment status same time operation
(until buzzer signals 3-times)
of the following keys
AEG Top Class daytime only
Time mode (P0) /Time minus (P2)
AEG Comfort Class daytime onlyTime mode (P0) /Time minus (P2)
Procedure of the test cycle
On operating the appropriate buttons a buzzer signal sounds 3 times after about 3 sec.
After about 3-4 seconds the door locks, the cooling fan starts at high speed. After about 40 50
seconds the door automatically unlocks, the fan stops.