7.3
Test and demo mode of door lock
Description of keys
Top class
Comfort class
7.3.1 Test of door lock for Top / Comfort class
Activating
To enter into door lock test the operator must execute the following actions:
In OFF state, press at the same time TMODE P0 key and MINUS P2 key (starting from left, last
and third-last key) for at least 800 ms; the successful in entering is feed-back to operator with 3
beeps.
In this mode door lock device is activated and deactivated continuously. To avoid overheating of the
door lock bimetallic heater, from lock to unlock and from unlock to lock, a puase of 20 seconds has
been done.
During the test if the door is closed Temperature lamp is on.
To exit from door lock service test, oven function knob must be moved from position 2. The door
lock phase ends when the system reaches the unlock state.
Deactivating
To stop the door lock test it is necessary to press main switch key P8 2 times.
In any case after 5 minutes, from entering, the door lock test ist stopped.