3-14
Operation
The water valve assembly is mounted
on the inside of the machine compart-
ment. The assembly consists of a dual
filter valve and a dual water/ice valve.
The water supply (copper) tubing is
connected to the inlet of the dual filter
valve. Plastic Y tubing is connected
from the outlet of the dual water filter
valve to the inlet of the water filter as-
sembly. From the filter a plastic tube
feeds the dual water/ice valves. The
dual valve controls the flow of filtered
water to the icemaker and to the water
dispenser.
When dispensing water, the filter valve
and the fountain valve are both ener-
gized simutaneously to provide fil-
tered water to founatin. During the fill
cycle of the icemaker the filter valve
and icemaker valve are both energized
simuatneously to provide filtered wa-
ter to the Icemaker.
The filter head assembly is mounted
to the back of the fresh food liner us-
ing two mounting screws. Plastic tub-
ing passes thought an opening in the
back of the cabinet. The ends of the
tubing connect to the inlet and outlet
fittings on the filter head.
Replacing the Filter Cartridge
The water filter mounts in the upper
fresh food compartment, on the un-
derside of the control housing. It is
recommended that the filter cartridge
be replaced every 6 months or sooner,
if the water flow to the dispenser or
icemaker decidedly decreases or if an
objectionable taste or odor occurs.
2. Twist the filter cartridge 1/4 turn coun-
terclockwise so the ears on the car-
tridge are able to disengage from the
filter head.
3. Carefully remove the replacement filter
from its packaging.
4. Apply the sticker to the cartridge to
remind you to replace the filter within 6
months.
5. Reinstall the new cartridge in reverse
order of removal.
6. Dispense 8 to10 glasses of water
through the dispenser to purge any air
from the system.
7. Carefully check for leaks.
1. Place a cloth or paper towel on the
shelf below the filter to catch any drops
of water that may fall when replacing
the filter.