The task of this system is to suppress leaky microwave
rays between oven and closed door.
-The wave trap, whose size and structure is depending
on the microwave length
-The door sealing of magnetic material in order to thus
absorb possible remaining radiation
The magnetic
sealing integrated
in the door
When opening the door, all 3 microswitches are actuated via at least two mechanical
systems. In doing so, primary and secondary switches interrupt the power supply.
If, for whatever reason, one of these switches does not open, the monitoring switch short-
circuits the entry circuit resp. high-voltage transformer. The triggering off of the fuse is
hereby accepted.
Safety first!!!
Mechanical safety system
-primary
-secondary
-monitor
Interlock-microswitch system
Electromagnetic safety system
created by TSE-N, Reiner Kurzke
Page 12