Drop-In Cooktop / Downdraft Vent 
Countertop Preparation Specifications

For detailed Drop-In Cooktop installation, refer to model-specific product
page and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.

Position cooktop/vent cutout so all required minimum clearances are met.

Minimum flat countertop area must meet or exceed combined overall
width and depth as shown. Standard 25" countertop depth may NOT be
adequate for some cooktop / vent installations, especially with backsplash.

Separate circuits required for cooktop and vent. 

(Refer to product-specific

electrical specifications.)

Always consult local and national electric and gas codes. Check local
building codes for installation requirements, as they may vary per locale.

Downdraft Vent Specifications

For detailed Downdraft Vent installations, refer to model-specific 
product page and installation guide on web.

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 1.0 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded 
for safe operation.)

Amps @ 120 Volts = 8.0 Amps

Vent unit outside of building only.

Vent must be installed in vertical orientation only.

1,600 CFM remote exhaust blower (PN # 5304444802) 
included with vent – shipped in separate box.

Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.

When multiple elbows are necessary, ensure a minimum of 24" of 
straight duct between any two elbows.

Thermal breaks such as short section of nonmetallic duct, should 
be used in areas of extreme cold.

For most efficient airflow exhaust, use a straight run or as few elbows 
as possible.

Cold weather installations should have additional backdraft damper
installed.

Installing a Downdraft Vent in combination with any gas cooking 
surface will affect optimum burner efficiency.

Note: For planning purposes only. Refer to Product Installation Guide 

on the web at electroluxicon.com for detailed instructions.

Drop-In Cooktop/Downdraft Vent
Countertop Preparation

High standards of quality at Electrolux Home Products, Inc. mean we are 

constantly working to improve our products. We reserve the right to change 

specifications or discontinue models without notice.

Electrolux Major Appliances, N.A.

USA

250 Bobby Jones Expressway 

Augusta, GA 30907 

1-877-4electrolux (1-877-435-3287) 

electroluxicon.com

CANADA

5855 Terry Fox Way 

Mississauga, ON L5V 3E4 

1-800-265-8352 

electroluxicon.ca

DIC_DDV_PREP  09/09

© 2009 Electrolux Home Products, Inc.

Printed in the U.S.A.

Countertop Preparation for 30" & 36" Drop-In Cooktop / Downdraft Vent Installation

2

9

/

16

"

1

/

4

" min.

flat ledge

Backsplash

3

/

4

" max.

  * Overall flat ledge behind

backside of cabinet front

** Minimum flat surface required

to fit top surface of cooktop
and downdraft vent cap

A

Vertical noncombustible surface - rear wall

25"

B

Top

23

 1

/

4

"

min.

Flush with

back side of

cabinet front

 D*

 E**

C

Stiffener

Back side of

cabinet front

Vent unit

2

1

/

8

"

Countertop
raised lip

Countertop
backsplash

Downdraft
chimney top

Cooktop

25"

(standard countertop)*

23

1

/

4

" min.

2

13

/

16

"

3"

Vertical noncombustible surface - rear wall

Studwall

3

/

4

" max. backsplash thickness

1

/

4

" min. flat ledge

1

15

/

16

"

9

/

32

"

2

13

/

16

"

Cooktop Installation Note:

To ensure proper installation, refer to model-specific installation
guide on web for cooktop dimensions, cutout dimensions and
cabinet requirements. Due to varying cooktop depths, tight fit
is possible between cooktop and vent.

Countertop Preparation Note:

Be aware of areas of potential interference called out in
illustration. Countertop with raised lip and/or backsplash may
not allow enough flat area for proper installation, 2-13/16"
of flat countertop required behind cooktop. No gap required
between back of cooktop and front of downdraft trim piece.

 

*Standard 25" countertop depth may NOT be adequate for

some cooktop / vent installations, especially with backsplash.

E30DD75ESS / 30" Cooktop Cutout Dimensions

30" Cooktops

A

B

C

D

E

E30EC65ESS

 30"

27 

3

/

4

"

20 

3

/

8

"

23 

3

/

16

"  24 

3

/

16

"

E30EC70FSS

 30"

27 

3

/

4

"

20 

1

/

4

"

23 

1

/

16

"  24 

1

/

16

"

E30GC64ESS

27 

1

/

2

"

27 

3

/

4

"

19 

7

/

8

"

22 

11

/

16

"  23 

11

/

16

"

E30GC70FSS

28 

1

/

2

"

27 

3

/

4

"

19 

3

/

4

"

22 

9

/

16

"  23 

9

/

16

"

E30IC80ISS

29 

3

/

4

"

27 

3

/

4

"

20 

1

/

2

"

23 

5

/

16

"  24 

5

/

16

"

E36DD75ESS / 36" Cooktop Cutout Dimensions

36" Cooktops

A

B

C

D

E

E36EC65ESS

 36"

33 

3

/

4

"

20 

3

/

8

"

23 

3

/

16

" 24 

3

/

16

"

E36EC70FSS

 36"

33 

3

/

4

"

20 

1

/

2

"

23 

5

/

16

"

24 

5

/

16

"

E36GC65ESS

33 

3

/

4

"

33 

3

/

4

"

19 

7

/

8

"

22 

11

/

16

" 23 

11

/

16

"

E36GC70FSS

34 

1

/

2

"

33 

3

/

4

"

19 

3

/

4

"

22 

9

/

16

" 23 

9

/

16

"

E36IC80ISS

 36"

33 

3

/

4

"

20 

1

/

2

"

23 

5

/

16

" 24 

5

/

16

"

For detailed cooktop and
downdraft vent installation
specifications, refer to
model-specific product
page and installation
guide on web

Содержание ICON E30DD75ESS

Страница 1: ...eparate box NOTE Always consult local and national electric codes Refer to Product Installation Guide for detailed installation instructions on the web at electroluxicon com Specifications subject to change Countertop Mount External Down 1600 10 Dial Yes Yes External 3 1 4 x 10 40 30 3 27 32 120V 60Hz 15A 1 0 Bottom Right 48 Lbs electroluxicon com Infinite Speed Control The ultraquiet blower allow...

Страница 2: ...lide In Cooktop Downdraft Vent Countertop Preparation pages on web Proper combination installation of Electrolux ICON Downdraft Vent model E30DD75ESS and approved 30 Gas Slide In Cooktop will require cooktop power cord to be relocated to underside of unit For details refer to 30 36 Gas Slide In Cooktop Power Cord Relocation Instructions on web Note For planning purposes only Refer to Product Insta...

Страница 3: ...ng to improve our products We reserve the right to change specifications or discontinue models without notice Electrolux Major Appliances N A USA 250 Bobby Jones Expressway Augusta GA 30907 1 877 4electrolux 1 877 435 3287 electroluxicon com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 electroluxicon ca DIC_DDV_PREP 09 09 2009 Electrolux Home Products Inc Printed in the U S A Co...

Страница 4: ...te For planning purposes only Refer to Product Installation Guide on the web at electroluxicon com for detailed instructions High standards of quality at Electrolux Home Products Inc mean we are constantly working to improve our products We reserve the right to change specifications or discontinue models without notice Electrolux Major Appliances N A USA 250 Bobby Jones Expressway Augusta GA 30907...

Отзывы: