30" Downdraft Vent Specifications
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.0 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120 Volts = 8.0 Amps
•
Do not use same circuit as cooktop.
•
Always consult local and national electric codes. Check local
building codes for installation requirements, as they may vary per locale.
•
1,600 CFM remote exhaust blower (PN # 5304444802) included
with vent – shipped in separate box.
•
Vent must be installed in vertical orientation only.
•
Vent unit outside of building only.
•
Exhaust Duct Required – 3-1/4" x 10" (3-1/4" x 10" to round transition
duct will be needed)
•
Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
•
When multiple elbows are necessary, ensure a minimum of 24" of
straight duct between any two elbows.
•
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.
•
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
•
Cold weather installations should have additional backdraft
damper installed.
•
Installing a Downdraft Vent in combination with any gas cooking surface
will affect optimum burner efficiency.
•
Downdraft Vents can NOT be used in combination with any cooktop
backsplash.
•
Downdraft Vent model E30DD75ESS is approved to be used in
combination with Electrolux ICON
®
Drop-In Cooktop models
E30EC65ESS, E30EC70FSS, E30IC75FSS, E30IC80ISS, E30GC64ESS,
E30GC70FSS;
and Electrolux ICON
®
Slide-In Cooktop model E30GC74GPS.
(For detailed countertop preparation, refer to Drop-In and Slide-In
Cooktop / Downdraft Vent Countertop Preparation pages on web.)
•
Proper combination installation of Electrolux ICON
®
Downdraft Vent model
E30DD75ESS and approved 30" Gas Slide-In Cooktop will require
cooktop power cord to be relocated to underside of unit.
(For details,
refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation
Instructions on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Downdraft Vent
E30DD75ESS
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
•
250 Bobby Jones Expressway
•
Augusta, GA 30907
•
1-877-4electrolux (1-877-435-3287)
•
electroluxicon.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
electroluxicon.ca
E30DD75ESS 09/09
© 2009 Electrolux Home Products, Inc.
Printed in the U.S.A.
For Use With
Duct Size
30" Cooktops
3
1
/
4
" x 10"
Specifications
Against-Wall
Downdraft
Installations
2
13
/
16
"
1
15
/
16
"
3"
Wallboard
Studwall
2
1
/
8
"
9
/
32
"
Cooktop/
Range
1
/
4
" min.
3
/
4
" max.
backsplash
thickness
Roof Exhaust
Blower
Stud wall
Backsplash
3
1
/
4
" x 10"
to round
transition
Wallboard
3
1
/
4
" x 10" duct
3
1
/
4
" x 10"
90
°
elbow
Anchoring leg
Finished floor
Roof
Cooktop
Vent unit
Motor cover
Exterior Wall Exhaust
Wallboard
Cooktop
Outside wall
Blower
Stud wall
Backsplash
3
1
/
4
" x 10" duct
3
1
/
4
" x 10"
90
°
elbow
Anchoring leg
Finished floor
Vent unit
Motor cover
Cap Profile
1
3
/
16
"
2
1
/
2
"
Front
Anchoring legs
1
5
/
8
" x 16" exhaust duct
Electrical access panel
8
1
/
2
"
3
1
/
4
" x 10"
rear exhaust
duct
30"
25
7
/
8
"
6"
Motor cover
10"
30"
1
5
/
8
" x 16"
exhaust ducts
27
3
/
4
"
Countertop
Finished
Floor
48", 3-prong,
grounded
power cord
Side
Stiffener
1
5
/
8
" x 16"
exhaust duct
3
1
/
4
" x 10"
exhaust duct
3
/
4
"
3
3
/
4
"
18
13
/
16
"
9
7
/
16
"
3
/
8
"
Finished Floor