Important
In this normal case of use, it is not necessary to connect the exhaust duct to the open air.
In the opposite case, the exhaust duct must be connected to the open air, by the shortest way, and with as few bents
as possible.
Incline the flexi-hose downwards, as compared to the machine.
Protect the end of the exhaust duct from the bad weather.
Do not connect the exhaust duct to a gas, coal, fuel oil furnaces chimney. Separate it also from any other ducting
(tumble dryer, finishing cabinet).
4.5
Electric power supply :
The feeder cable sections mentioned in our literature are given
only as a guide
.
To obtain a value perfectly suited to your own application and which takes account of the different correction factors
in respect of your plant, refer to the tables below.
4.5.1
TABLE 1 (in accordance with EN standard 60204–1)
Values given for :
Cable with copper conductors.
Cable with PVC insulation (for other insulants see TABLE 3).
Ambient temperature 40°C max. (for others see TABLE 2)
Three-phase cable under load without including starting currents.
BT / C / E cable layout.
MAXIMUM ADMISSIBLE CURRENT
Cable section
Seated in Cable Duct
or Cable Trough
B2
Wall Fixing
C
Cable Tray
E
3 x 1.5 mm²
12.2 A
15.2 A
16.1 A
3 x 2.5 mm²
16.5 A
21 A
22 A
3 X 4 mm²
23 A
28 A
30 A
3 x 6 mm²
29 A
36 A
37 A
3 x 10 mm²
40 A
50 A
52 A
3 x 16 mm²
53 A
66 A
70 A
3 x 25 mm²
67 A
84 A
88 A
3x 35 mm²
83 A
104 A
114 A
3 x 50 mm²
-
123 A
123 A
3 x 70 mm²
-
155 A
155 A
4.5.2
TABLE 2 correction factors for different ambient temperatures :
Ambient temperature
Correction factor
30 ° C (86° F)
1.15
35 ° C (95° F)
1.08
40 ° C (104° F)
1
45 ° C (113° F)
0.91
50 ° C (122° F)
0.82
55 ° C (131° F)
0.71
60 ° C (140° F)
0.58
Содержание IC6 48 FFS Series
Страница 1: ...Installation manual Ironers IC6 48xx FFS Original language 10102059 EN ...
Страница 2: ......
Страница 15: ...Installation manual 15 ...
Страница 29: ...Installation manual 29 Proceed in reverse order in case of transport of the machine ...
Страница 34: ...34 Installation manual ...
Страница 53: ...Installation manual 53 ...
Страница 63: ...Installation manual 63 Important Adjustments should be made by qualified personnel only ...
Страница 71: ......