32
Installation manual
3.4
Electrical connection
Prior to use, the machine should be plugged into a correctly earthed power socket complying with the standard in
force.
Important
The mechanical and electrical installation of the machine should only be done by qualified personnel.
Important
Make sure that both the power voltage is correct and the power supply of your installation is sufficient before con-
necting the machine.Use only a cable to supply the machine.
Caution
The main switch is located on the rear side of the machine , identified by this sticker.
The use of power electronics (variator or filter for example) may lead to unexperted release of breakers with 30mA
differential current device.
To avoid these untimely activations, you ought to use differential protecting systems with residual current only, having
a high level of immunity as regards leakage transient current.
This type of breaker should thus be avoided, or a value of 300mA maximum should be observed according to stand-
ard NFC 15100.
For operation that will take place with power supply or/and machine power on, technicians who will operate must
have approval to work Low-voltage (1000V Ac max or 1500V DC) and use suitable safety equipment and tools.
To be in accordance with the Low-voltage authorization if the machine have the option electrostatics bar, this one
must be disconnect during technician operation, unless the technicians has a High-voltage authorization.
Содержание IC6 48 FFS Series
Страница 1: ...Installation manual Ironers IC6 48xx FFS Original language 10102059 EN ...
Страница 2: ......
Страница 15: ...Installation manual 15 ...
Страница 29: ...Installation manual 29 Proceed in reverse order in case of transport of the machine ...
Страница 34: ...34 Installation manual ...
Страница 53: ...Installation manual 53 ...
Страница 63: ...Installation manual 63 Important Adjustments should be made by qualified personnel only ...
Страница 71: ......