Service
Manual
9406
Installing the circuit board
•
Plug in the connectors from the keyswitch and the
ribbon cable. Note that the ribbon cable must be
folded as shown in order to be plugged in the right
way round.
•
Check that the guard strip between the board and
the control panel (see sketch) is in position.
•
Secure the board with the 6 screws and put back
the board connectors and the tube to the level
detector.
Removing the control panel and
circuit board
•
Unplug the board connectors and the tube to the
level detector.
•
Remove the two metal clips by pulling them
straight upwards.
•
Pull the unit forward and outward so that the two
metal tongues unlatch from the fixing eyelets.
23. Programmer
23
1380
Ribbon cable
Guard strip
1378
Installing the ribbon cable
Removing the control panel and circuit board
Metal clips
Fixing
eyelet
Tube to level detector
5
Example FLE 360
Содержание FLE120