Additional Information On Use
Tips on saving energy
Below are some simple ways to save
energy when you use your Heatpump.
Set the correct temperature
• Setting the thermostat 1°C higher than the
desired temperature in the COOL mode
and 2°C lower in the HEAT mode will save
approximately 10 percent in power con-
sumption.
• Setting the temperature lower than
necessary during cooling operation will re-
sult in increased power consumption.
Block direct sunlight and prevent drafts
• Blocking direct sunlight during cooling
operation will reduce power consumption.
• Close the windows and doors during cool-
ing and heating operations.
Set proper air flow direction to obtain the
best air circulation
Keep filter clean to ensure the most efficient
operation
Make most of the timer off function
Disconnect the power cord when the unit is
not used for an extended period of time
• The indoor unit still consumes a small
amount of power when it is not operating.
Operating temperature range
Indoor temp.
Outdoor temp.
Heating
upper limit
27
˚
C
24
˚
C
lower limit
5
˚
C
–20
˚
C
Cooling
upper limit
32
˚
C
43
˚
C
lower limit
21
˚
C
–10
˚
C
• The built-in protective device may prevent
the unit from operating when used out of
this range.
• Condensation may form on the air outlet if
the unit operates continuously in the
COOL or DRY mode when humidity is over
80 percent.
When power failure occurs
This Heatpump has a memory function to
store settings when a power failure occurs.
After power recovery, the unit will
automatically restart in the same settings
which were active before the power failure,
except for timer settings.
If the timers were set before a power failure,
they will need to be re-set after power recov-
ery.
Preheating function
In the HEAT operation, the indoor fan may
not start for two to five minutes after the unit
is turned on to prevent cold air from blowing
out of the unit.
De-icing function
• When ice forms on the heat exchanger in
the outdoor unit during the HEAT opera-
tion, an automatic de-icer provides heat
for about 5 to 10 minutes to remove the
ice. During de-icing, the inside and outside
fans stop operating.
• After de-icing is completed, the unit
automatically resumes operation in the
HEAT mode.
Heating efficiency
• The unit employs a heat pump that draws
heat from the outside air and releases it
into the room. The outside air temperature
therefore greatly affects the heating
efficiency.
• If the heating efficiency is reduced due to
low outside temperatures, use an
additional heater.
• It takes time to warm up and heat the entire
room because of the forced air circulation
system.
Cleaning And Care
Caution!
Be sure to disconnect the
power cord from the wall outlet or turn
off the circuit breaker before performing
any maintenance.
Cleaning the filters
The air filters should be cleaned every two
weeks.
1. Turn off the unit.
2. Remove the filters.
16