Technical Support - A.D.L. 02 / 2011
18/24
599 74 08-64
ALA
R
M
CO
DE
Description
Possible fault
Action
Machine status
Reset
E41
Door open
Check whether the door is closed properly.
Faulty
wiring.
Door safety interlock faulty.
Main circuit board faulty.
Cycle paused
CLOSE THE
DOOR
E42
Problems with door lock
Faulty
wiring.
Door safety interlock faulty.
Electrical current leak between heating element and ground.
Main circuit board faulty.
Cycle paused
START/RESET
E43
Faulty triac supplying power to
door delay system
Faulty
wiring.
Door safety interlock faulty.
Main circuit board faulty.
Safety drain cycle.
Cycle blocked
RESET
E44
Faulty sensing by door delay
system
Main circuit board faulty.
Safety drain cycle.
Cycle blocked
RESET
E45
Faulty sensing by door delay
system triac
Main circuit board faulty.
Safety drain cycle.
Cycle blocked
RESET
E51
Motor power triac short-circuited
Faulty
wiring.
Motor
faulty.
Main circuit board faulty.
After 5 attempts, cycle blocked with door
unlocked.
ON/OFF
RESET
E53
Faulty sensing by triac motor.
Input voltage to microprocessor
incorrect.
Main circuit board faulty.
Cycle interrupted.
RESET
E54
Motor relay contacts sticking
(high voltage level when the relay
switches to OFF).
Current leakage from the motor.
Current leakage from the cabling.
Main circuit board faulty.
Cycle blocked with door locked after 5 attempts.
RESET