Technical Support - A.D.L. 02 / 2011
6/24
599 74 08-64
3 DIAGNOSTIC
SYSTEM
3.1 Accessing
diagnostics
Do not start the procedure with the combination buttons pressed
Series 6
Series 7
Turn the appliance on at the
ON/OFF switch.
Only in the aesthetics 6 turn the
switch to the first position to the
right.
Press the
START/PAUSE
button
and the nearest
option button
simultaneously (as shown in
the figure).
Hold the buttons/sensors
down/pressed until the LEDs and
symbols begin to flash in sequence
(approximately 3 seconds).
In the first position, the operation of the buttons, of the related LEDs and of the groups of symbols shown on the
LCD screen is checked; turn the programme selector dial
clockwise
to run the diagnostic cycle for the
operation of the various components and to read any alarms (see diagnostic test).
During this phase, if any key combination is pressed (except for the one relating to diagnostics), all the
combinations of options stored are deleted (Extra rinse, No buzzer, etc..) whereas for SERIES 9, the memories
with the customised programmes are also deleted.
3.2
Quitting the diagnostics system
To exit the diagnostic cycle, switch the appliance off, then back on and then off again.