POSEIDON 5 - NA5 
SERVICE MANUAL 
 

ENGLISH 

Summary of Contents for Poseidon 5 Series

Page 1: ...POSEIDON 5 NA5 SERVICE MANUAL ENGLISH ...

Page 2: ...illustrated spare parts lists during repairs They show the assembly position and the sequence in which the individual components should be assembled See Technical Service Bulletin TSB sheets They include information on technical modifications that have been made after this repair manual was printed Technical Service Bulletin sheets are also valid as a supplement to the spare parts list until publi...

Page 3: ...C D E F G H I Special tools Spare parts Wiring diagrams Adjustment Test Service Repair Troubleshooting Function Construction Technical data Safety instructions 66 59 65 56 58 47 55 43 46 36 42 30 35 6 29 5 ...

Page 4: ...on Overview Unit 30 Overview complete motor pump 31 D Function Electrical 36 Funktion PCB 37 Schematic function 39 E Troubleshooting Table 43 Failure description 45 F Service Repair Indification 47 Chassis 47 Unloader By pass valve 48 Pump 50 Wobble disc motor 54 G Adjustment Test Torque settings 56 ...

Page 5: ...em readily available Repair work should be carried out by persons instructed in electrical installations or by trained electricians only Take the following ESD precautions before carrying out any repairs to the electronics Touch the earth conductor before repairing the cleaner to discharge electrostatic charge from your body Wear wrist band if necassary Use a conductive floor covering or a conduct...

Page 6: ...trol ALPHASyn 150 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420558 Unit Data Nozzle size water NT 0475 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary La...

Page 7: ...ASyn 150 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420558 Unit Data Nozzle size water NT 0475 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary Lance Type ...

Page 8: ...P Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420554 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary L...

Page 9: ...P Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1740 Electrical diagram no 106420554 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary L...

Page 10: ...e BP Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420550 Unit Data Nozzle size water NT 0400 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primar...

Page 11: ...type BP Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1740 Electrical diagram no 106420564 Unit Data Nozzle size water NT 0400 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Pri...

Page 12: ...ump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420550 Unit Data Nozzle size water NT 0400 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary Lance Type FLEXOPOWER...

Page 13: ... BP Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420564 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary...

Page 14: ...P Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420550 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary L...

Page 15: ...e BP Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1740 Electrical diagram no 106420564 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primar...

Page 16: ...Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420552 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary Lan...

Page 17: ...ol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420564 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary Lance Ty...

Page 18: ... GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420550 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary Lance Type...

Page 19: ...P Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420550 Unit Data Nozzle size water NT 0530 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary L...

Page 20: ...e BP Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1740 Electrical diagram no 106420564 Unit Data Nozzle size water NT 0530 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primar...

Page 21: ...220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420552 Unit Data Nozzle size water NT 0530 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary Lance Type TORNA...

Page 22: ...ump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420550 Unit Data Nozzle size water NT 0530 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary Lance Type TORNADO PL...

Page 23: ...il type BP Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1740 Electrical diagram no 106420566 Unit Data Nozzle size water NT 0650 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK ...

Page 24: ...astrol ALPHASyn 150 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420559 Unit Data Nozzle size water NT 0435 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 ST GUN W HOSE SWIVEL GERNI Prima...

Page 25: ...p oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420550 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 ST GUN W HOSE SWIVEL GERNI Primary Lance Type TORNADO P...

Page 26: ...e BP Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420550 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primar...

Page 27: ...ump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420550 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary Lance Type FLEXOPOWER...

Page 28: ... BP Energol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420550 Unit Data Nozzle size water NT 0400 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary...

Page 29: ...gol GR XP220 Pump oil amount l 0 73 Electric Electric data Control voltage V Highvoltage HV test voltage V 1 5 HV Insulation resistance 1 Earth circuit resistance 0 2 Pump revolutions 1450 Electrical diagram no 106420550 Unit Data Nozzle size water NT 0500 Max Inlet temp primed C Max Inlet temp suction C 40 Max Inlet temp pressure fed C 60 Gun Type ERGO 2000 STD INCL SWIVEL NILFISK Primary Lance T...

Page 30: ...verview Poseidon 5 NA5 Lance Lance holder top Water inlet Filter ON OFF switch Pic C1 POSEIDON 5 NA5 Lance holder bottom Water outlet Pressure gauge View for oil container Detergent valve Detergent Bottles Cabinet lock Pic C2 POSEIDON 5 Cabinet frame parts ...

Page 31: ...view Poseidon 5 NA5 Pic C3 Poseidon 5 NA5 without cabinet Pressure gauge Injector Unloader valve Cylinder head Water outlet Water inlet Electrical box Water regulation D bearing cover Detergent valve ON OFF switch Pump oil lid Pump oil container Cylinder block ...

Page 32: ...Unloader piston Micro switch housing Water regulation Unloader spring Activation arm Non return valve for water regulation By pass opening valve Non return valve Injector nozzle Unloader housing Injector valve Overview Poseidon 5 NA5 unloader PA Models Pic C4 Unloader ...

Page 33: ... POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 33 C Water regulation Flow piston By pass valve Injector valve Injector nozzle Reed contact Unloader housing Overview Poseidon 5 NA5 By pass valve FA Models Pic C5 By pass valve ...

Page 34: ..._20 12 34 C Pic C6 Pump parts Piston Washer for spring Spring Cylinder block Thrust collar Oil seals Cylinder head Water inlet Pressure valve Secondary seal Support ring Back up ring Primary seal Header ring Inlet valve Overview NA 5 pump unit ...

Page 35: ...5 Motor Pump Motor complete Fan Oil Tank End bearing cover D bearing cover Lid for oil tank Oil seal Oil plug Pic C7 Motor pump unit Radial ball bearing Cylindrical roller bearing Pressure disc Wobble disc Radial ball bearing Fan cover Cylindrical roller bearing with ...

Page 36: ...e contacts of S1 and K1 Machine is still off Main switch S1 in position 1 ON Spray gun is closed machine builds up pressure if B4 cut off pressure not reached and B3 motor winding temp Below 160 C or 320 F automatic reset of B3 are closed if cut off pressure is reached B4 opens and the machine stops If spray gun is activated pressure in unloader drops B4 closes and starts the motor water flows at ...

Page 37: ...achine is finished 3 To run the motor in by pass for 20 sec after flow stop was reached and B4 opened 4 To record and store data concerning the machines work stiuations operation and by pass The PCB is protected by a fuse 6 3A slow placed on the board Pre conditions Machine hooked up to adequate water and powerr supply Main switch S1 in position 0 OFF There is mains voltage at the contacts of S1 a...

Page 38: ...ted within 20 sec Motor stops in Stand by mode STAND BY Mode Motor is switched off Micro switch open If the gun is activated The motor starts and goes to Run mode SLEEP Mode If the gun isn t activated within 30 minutes the unit will not restart automatically It has to be restarted at the main switch If the micro switch closes in time intervals t 1 5 sec it is recognised as a leakage as an activati...

Page 39: ...ed by the outlet pressure exceeding the pressure from the unloader spring the By pass ball 6 is moved forward and opens the connection between the water inlet and the water outlet blue arrows The micro switch 2 is activated by the activation arm 3 and the motor pump 1 stops Now the non return valve piston 7 is pressed against its seat which keeps the pressure high in the hose and on the backside o...

Page 40: ...spray gun 8 is now activated The non return valve 7 opens the pressure in the hose drops and release the pressure on the backside of the unloader piston 5 The unloader spring 4 presses the unloader piston 5 backwards and drags the activation arm 3 away from the micro switch 2 and the motor pump 1 starts The pressure rises to working pressure and remains constant during operation 1 2 3 6 4 5 7 8 Mo...

Page 41: ...nloader working pressure open gun and reduced water volume Pressure Activated Unloader closing gun and reduced water volume 1 2 3 1 2 3 4 1 Valve for water reduction open 2 Water can pass through non return valve 3 Water can pass through water outlet 1 Valve for water reduction open 2 Non return valve is closing 3 Non return valve in outlet is closing 4 Connection between water inlet and water out...

Page 42: ...er the lower piston the by pass valve is closed and the machine runs in working mode When the spray gun is closing the flow shortly stops and the pressure rises The opening pressure valve shortly opens the pressure on both sides of the lower piston equalizes and the lower by pass piston lifts up and open the by pass Flow Activated By pass system working pressure open gun Pic D9 By pass valve open ...

Page 43: ...chnical data part B Pressure fluctuations Lack of water Water inlet hose is too long or its cross section too small Lack of water caused by blocked water filter Lack of water because max permissible suction height has not been heeded Pump sucks in air suction mode Open water tap Use specified water inlet hose Refer to user manual Clean the water filter in the water connection Never work without wa...

Page 44: ...ain voltage and the cleaner voltage are the same Switch off the cleaner and allow it to cool for at least 3 minutes Change the high pressure Cleaner starts stops by itself Leakage on high pressure side Locate the leak and repair it See next page No detergents drawn in Injector is dirty or suction hose is blocked Detergent container empty The cap on the nozzle is not set at low pressure Clean Top u...

Page 45: ... ring 11 Seat 13 defective System leaks internally or piston 12 closes too slowly caused by dirt chalk Remedy Replace Non return valve kit or clean dirty parts Symptom Machine starts by itself and stops right away Cause Pressure system leaks between spray gun and pump Cut off pressure drops and the activation arm 3 releases the micro switch 5 or leaks at gaskets 6 8 10 11 Remedy Check gaskets in s...

Page 46: ...ston 2 is stuck Remedy Replace defective parts Symptom Irregular working pressure Cause Injector nozzle 4 is worn Remedy Replace injector nozzle Symptom Low working pressure Cause By pass valve kit worn and leaks water Remedy Replace By pass valve kit Symptom Suction inlet for detergent leaks water Cause Non return valve 5 defective Remedy Replace non return valve Pic E2 By pass valve ...

Page 47: ...is manual chapter A Pic F1 Data Plate Pic F2 Cabinet Pic F3 E box 1 1 The lid for the electrical box is fitted with 2 x torx T20 screws Remove the screws and push the lid backwards to open the E box The oil container is fitted to the pump by the 2x Torx 20 screws The cabinet is demounted by turning the two lock screws 1 on top of the cabinet Open the cabinet and pull forward ...

Page 48: ...rn valve seat is mounted use silicon grease to protect the o rings against damages When the unloader piston is defective replace the complete repair kit to ensure all related parts are in a proper condition Use silicon grease to protect gaskets against damages Pic F6 Water outlet Injector The injector nozzle is placed in the water outlet and is demounted with a 10mm socket wrench Inside the hose t...

Page 49: ...housing Pic F11 Unloader housing Dismount the unloader housing 3 from the valve housing 1 by the three M6 bolts 4 By reassembling mount the smallest o ring 6 in the unloader 3 and the biggest o ring 5 in the water inlet part 2 Use silicone grease and stretch the o rings over the parts do not roll the o rings Pic F12 Oil drain fill Drain off the oil by dismounting the 14mm oil plug 1 After repair r...

Page 50: ... dismounting the thrust collar Inspect the thrust collar for damages before mounting Pic F14 Thrust collar Pic F13 Valve housing Pic F15 Valve housing Pic F16 Valve housing Carefully tip out the sleeves with an adequate puller or screwdriver and replace them Be careful not to scratch the surface Knock carefully on the back side of the valve seat to demount it or use an 8mm threaded pin and pull it...

Page 51: ...emble header ring in right position Knob on header ring must be placed in groove in cylinderhead Drop do not knock it into the right position Pic F 18 Header ring If the header ring is mounted wrongly and not according to instruction there is a big risk of damaging the header ring and parts of it will block pistons and valves in the pump or get stucked in the non return valve in the unloader Pic F...

Page 52: ...h new parts if necessary Picture of piston guides The pressure valves can easily be taken out of the cylinder head Replace with new parts if necessary Pic F23 Cylinder block Cylinder Block Pic F24 Oil Sleeves Overview of the placement of the parts in the cylinder block Take out the oil sleeves using an adequate puller or a screwdriver Be careful not to damage the surface of the cylinder block NEW ...

Page 53: ...ner and a fiber hammer Place sleeves pistons and springs as shown Mount the cylinder block to the D bearing cover by the two 6mm mounting screws Wobble disc The cylinder head and the cylinder block is fastend to the D bearing cover by two 6mm mounting bolts for the cylinder block and three 12mm bolts for the cylinder head Pic F27 Pump head Pic F28 D bearing cover and wobble disc Overview of the pa...

Page 54: ...the motor shaft and ensure the rotor to be kept in the right position in proportion to the stator Wobble disc Pic 16 Replace the complete wobble disc system and make sure parts are assembled according to instructions pic 17 pic 18 pos A B B A Pic 17 The curved edge A of the bearing tracks must be mounted against the D bearing cover and the wobble disc Pic 18 The sharpe edge B of the bearing track ...

Page 55: ...ur 6mm bolts When the bearing is damaged always replace the complete D bearing cover Pic F36 fan The oil sleeve in the D bearing cover can be demounted carefully using a screwdriver Mount the oil sleeve by using an adequate box spanner and a fiber Overview of the motor parts The fan can be demounted by taking off the lock ring and carefully push the fan with a screwdriver Electrical motor ...

Page 56: ...ed by tightning or loosening the unloader spring Follow the pressure values stated in the Technical data sheets in chapter B and read out the pressure on the pressure gauge with valve mounted on the pump outlet Pic G1 Unloader spring Pic G2 Adjustment of unloader spring Pic G3 Pressure gauge with valve Special tool no 1206358 ...

Page 57: ...p screws etc must have a temperature at max 20 C or as the surroundings The only Adjustment to be made on the by pass system is the opening pressure valve Safety valve Always adjust the pressure to be approx 25 30 bar higher than normal pressure Pic G4 Opening pressure valve Unloader Retaining pressure settings ...

Page 58: ...m Test Screw Unbracho 6 14 Nm M4 pointed screw Unbracho 4 5 Nm Outlet fitting Detergent studs NV 17 20 Nm Venturi NV 8 1 4 Nm Pump Head 3 M12 screws for pump assy Unbracho 10 65 Nm Thrust collar Pull out tool N A Outlet valves Pull out tool N A Inlet valves Mandrel and hammer N A Primary seals ø20 seal tool N A Cylinderblock 2 M8 service screws Unbracho 6 20 Nm Oil seals Ring and hammer N A Wobble...

Page 59: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 59 H 106420550 ...

Page 60: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 60 H 106420552 ...

Page 61: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 61 H 106420554 ...

Page 62: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 62 H 106420558 ...

Page 63: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 63 H 106420559 ...

Page 64: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 64 H 106420564 ...

Page 65: ...Wiring diagrams POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 65 H 106420566 ...

Page 66: ...ools 1206358 Test Pressure Gauge Adjustment cut off pressure Spare Parts Additional Materials 41455 Grease 15 C to 130 C Valve grease 107144146 Pump oil Energol GR XP 220 Includes all important repair kits and parts necessary for service and maintenance For a detailed view have a look in the Spare Parts List ...

Page 67: ...67 POSEIDON 5 NEW NA5_en_Ver 1 0_20 12 Notes ...

Page 68: ...Nilfisk ALTO Division of Nilfisk Advance A S Industrivej 1 9650 Hadsund Denmark ...