background image

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL

2

IMPORTANT SAFETY INSTRUCTIONS

Installation of this range must conform with local codes or,
in the absence of local codes, with the National Fuel Gas
Code ANSI Z223.1—latest edition when installed in the
United States.

When installed in a manufactured (mobile) home,
installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
[formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD (Part 280)] or, when
such standard is not applicable, the Standard for
Manufactured Home Installations, ANSI/NCSBCS A225.1,
or with local codes.

Proper Installation—Be sure your appliance is properly
installed and grounded by a qualified technician in
accordance with the National Fuel Gas Code ANSI
Z223- latest edition, or in Canada CAN/CGA B149.1 and
CAN/GGA B149.2,  and the National Electrical Code
ANSI/NFPA No.70-latest edition, or in Canada CSA
Standard C22.1, Canadian Electrical Code, Part 1, and
local code requirements.
 Install only per installation
instructions provided in the literature package for this
range.

This range has been design certified by CSA International.
As with any appliance using gas and generating heat,
there are certain safety precautions you should follow. You
will find them in the Use & Care Guide, read it carefully.

Special instructions for appliances installed in the State of
Massachusetts: This appliance can only be installed in the
State of Massachusetts by a Massachusetts licensed
plumber or gas fitter. When using a flexible gas connector,
it must not exceed 3 feet (36 inches) in length. A “T” handle
type manual gas valve must be installed in the gas supply
line to this appliance.

Be sure your range is installed and grounded
properly by a qualified installer or service
technician.

This range must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA No.
70 —latest edition when installed in the United
States.
 See "Grounding Instructions" on page 7-9 in
the Installation Steps.

Before installing the range in an area covered with
linoleum or any other synthetic floor covering,
make sure the floor covering can withstand heat at
least 90°F above room temperature without
shrinking, warping or discoloring.
 Do not install the
range over carpeting unless you place an insulating
pad or sheet of 1/4-inch thick plywood between the
range and carpeting.

To eliminate the need to reach over the surface
burners, cabinet storage space above the burners
should be avoided.

Adjust surface burner flame size so it does not
extend beyond the edge of the cooking utensil.
Excessive flame is hazardous.

Do not use the oven as a storage space. This
creates a potentially hazardous situation.

Never use your range for warming or heating the
room.  
Prolonged use of the range without adequate
ventilation can be dangerous.

Do not store or use gasoline or other flammable
vapors and liquids near this or any other appliance.
Explosions or fires could result.

Reset all controls to the "off" position after using a
programmable timing operation.

FOR MODELS WITH SELF-CLEAN FEATURE:

Remove broiler pan, food and other utensils before
self-cleaning the oven. 
Wipe up excess spillage. Follow
the cleaning instructions in the Use & Care Guide.

Unlike the standard gas range, THIS
COOKTOP IS NOT REMOVABLE. 
Do
not attempt to remove the cooktop.

Make sure the wall coverings around the range can
withstand the heat generated by the range.

Do not obstruct the flow of combustion air at the
oven vent nor around the base or beneath the
lower front panel of the range. 
Avoid touching the
vent openings or nearby surfaces as they may
become hot while the oven is in operation. This range
requires fresh air for proper burner combustion.

Do not store items of interest to children in the
cabinets above the range. 
Children could be seriously
burned climbing on the range to reach items.

  DO NOT MAKE ANY ATTEMPT TO

OPERATE THE ELECTRIC IGNITION OVEN DURING
AN ELECTRICAL POWER FAILURE. RESET ALL OVEN
CONTROLS TO "OFF" IN THE EVENT OF A POWER
FAILURE.

The electric ignitor will automatically re-ignite the oven
burner when power resumes if the oven thermostat control
was left in the "ON" position.

When an electrical power failure occurs during use, the
surface burners will continue to operate.

During a power outage, the surface burners can be lit with
a match. Hold a lighted match to the burner, then slowly

turn the knob to the 

 (lite) position. Use extreme caution

when lighting burners this way.

Содержание EW3LDF65GS

Страница 1: ...witch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier 1 Important Note to the Consumer Keep these instructions with your Use Care Guide for future...

Страница 2: ... synthetic floor covering make sure the floor covering can withstand heat at least 90 F above room temperature without shrinking warping or discoloring Do not install the range over carpeting unless you place an insulating pad or sheet of 1 4 inch thick plywood between the rangeandcarpeting To eliminate the need to reach over the surface burners cabinet storage space above the burners should be av...

Страница 3: ...e conduit for connection of the range Fig 19 Power cord 40 50 ampere rated Cord Kit 48 MAXIMUM LENGTH Fig 20 4 or 3 wire 40 50 ampere rated wall receptacle and mounting plate Fig 21 Copper electrical wiring and metal conduit for hard wiring installation only Tools you will need Wear safety glasses when using tools For leveling legs and Anti Tip Bracket Adjustable wrench or channel lock pliers Fig ...

Страница 4: ...ond the bottom of the cabinets INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL Do not seal the range to side cabinets Do not pinch the power supply cord between the range and the wall If cabinet depth is greater than 25 the oven front frame must extend beyond cabinet front by 1 2 minimum All openings in the wall or floor where the range is to be installed must be sealed Install a flush mount ...

Страница 5: ...low the bracket to fit flush against wall remove molding or mount bracket to floor For wall mount Fig 24 locate the bracket by placing the back edge of the template against rear wall and the side edge of template on the mark made referencing the side of the range Place bracket on top of template and mark location of the screw holes in wall If rear of range is further than 1 1 4 from wall when inst...

Страница 6: ...in Installation Steps for 4 or 3 Wire connections This appliance must be properly installed and grounded by aqualifiedtechnicianinaccordancewiththeNationalElectrical CodeANSI NFPANo 70 latestedition andlocalelectrical coderequirements This appliance may be connected by means of permanent Hard Wiring or Power Supply Cord Kit When hard wiring do not leave excess wire in range compartment Excesswirei...

Страница 7: ...29 30 31 32 2 Insert the end connectors for Line 1 Line 2 and Neutral and tighten securely to the terminal block IMPORTANT NOTE DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed 3 You must disconnect the ground strap Remove the factory installe...

Страница 8: ...nections ONLY A ground strap is installed on this range which connects the center terminal of the terminal block neutral to the range chassis The ground strap is connected to the range by the center lowest screw See Fig 34 The ground strap must not be removed unless national or local codes do not permit use of ground strap NOTE If the ground strap is removed for any reason a separate ground wire m...

Страница 9: ...ction may occur if these 3 nuts are loosened or removed NOTE For 3 Wire Permanent Connections skip Steps 3 4 and continue with Step 5 3 4 Wire Permanent Connection ONLY Disconnect the ground strap Remove the factory installed ground screw plate to release the factory installed copper ground strap from frame of the appliance Cut and discard the copper strap from the terminal block KEEP the ground s...

Страница 10: ...noutsideofthe range Be sure you know how and where to shut off the gas supply to the range Figs 16 37 3 InstallFlareAdapter togasPressureRegulator Figs 19 37 DonotallowthePressureRegulatortoturn on pipe when tightening fittings 4 Attach flexible Appliance Conduit to Flare Adapter on Pressure Regulator Figs 18 37 5 Install 2nd Flare Adapter to external manual Shut Off Valve Figs 19 37 6 Attach flex...

Страница 11: ...e burner knob counterclockwise to the lite position You will hear the igniter sparking Fig 39 2 The surface burner should light when gas is available to the top burner Purge air from supply lines by leaving knob in the lite position until burner ignites Each burner should light within four 4 seconds in normal operation after air has been purged from supply lines 3 Visually check that the burner ha...

Страница 12: ...age or warmer drawer or the lower panel area See Fig 41 When ordering parts for or making inquires about your range always be sure to include the model and serial numbers and a lot number or letter from the Serial Plate on your range The Serial Plate will also inform you of the rating of the burners the type of fuel and the pressure the range was adjusted for when it left the factory Before you ca...