TSE-P 10.00 FV
32/38
599 34 41-93
DISASSEMBLY OF GAS SOLENOID VALVE
To disassemble the gas control solenoid valve it is necessary to:
- Disconnect the gas connection.
- Disassemble the rear panel.
- Disconnect the connection wires, marking the
various positions.
- Unscrew the nuts which secure the gas inlet and
outlet to the solenoid valve
- Remove the screws from the solenoid valve
assembly and detach the solenoid valve from the
support bracket
Fig. 44
1 - GAS CONNECTION PIPE BETWEEN SOLENOID
VALVE AND BURNER
2 - ELECTRONIC PROGRAMMER
3 - GAS SOLENOID VALVE
4 - GAS INLET PIPE
Fig. 45
1 - GAS SOLENOID VALVE
2 - FIXING SCREWS
Fig. 46
1 - GAS SOLENOID VALVE
2 - VALVE ASSEMBLY FIXING SCREWS
3 - SUPPORT BRACKET FOR VALVE ASSEMBLY