TSE-P 10.00 FV
22/38
599 34 41-93
SECURING THE OVEN TO THE CABINET
1
. Fit the oven into the cabinet recess,
2 . Open the oven door
3 . Secure the oven to the kitchen cabinet with four
wood screws, which fit the holes provided in the
oven frame.
Fig. 25
ELECTRICAL CONNECTION
The oven is designed to be connected to 230-240V
(50Hz) electricity supply.
The oven has an easly accessible terminal block
which is marked as follows:
Letter L
- Live terminal
Letter N
- Neutral terminal
or E
- Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.
It is necessary to install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3 mm between the switch
contacts and of a type suitable for the required load
in compliance with the current safety legislation.
The switch must not interrupt the yellow and green
earth cable at any point.
Important
After installation and connection, the cable must be
placed so that it cannot at any point reach a
temperature of more than 60°C above the ambient
temperature.
Before the oven is connected, check that the main
fuse and the domestic installation can support the
load and that the power supply is properly earthed.
For UK use only
Connection
via
Min. size
Cable/flex
Cable/flex
type
Fuse
• 13 A socket
outlet
• 13 A
spur box
2.5 mm
2
3 core
butyl
insulated
13 A
min.
• Cooker
Control
Circuit
2.5 mm
PVC/PVC
twin and
earth
13 A
The manufacturer disclaims any liability should
these safety measures not be observed.
For Europe only
Min.size Cable/flex
Cable / flex type
Fuse
1,5 mm
2
H05 RR-F