EN Publication
number
599 71 19-22
Rev. 01
02/2009
PR - 42/42
Cleaner with radio remote:
-
Investigate if the LED on the remote indicates transmission. If not, change
battery and try again.
-
If still no LED indication on remote, change remote control and reprogram
the cleaner according to above instruction.
-
If LED indicates transmission, try replacing the remote according to above
instruction. If cleaner starts, replace the RF remote control.
-
If still no function, replace the control unit in the cleaner. Be aware of the
position of the radio antenna. If replacing the control unit this has to learn the
RF-remote address according to above description.
Cleaner with active motor nozzle:
-
Check the bent end, test with another HBTN. If possible to change power
setting, change.
-
Check wiring from hose connection to 2G active PCB.
-
Change 2G active PCB, test.
-
Check wiring between 2G active PCB and control unit for failure or bad
connection.
-
Change the control unit.
If the power regulation works for the first minutes after start, and then stops
working. Motor seems to run only in maximum speed.
-
Check the cooling system to the Power module (tube, cooling house, tube
connection to dust compartment).
-
Change the Power module PCB.
Auto function doesn’t
work properly
-
Check tube connection between hose connection and Auto PCB.
-
Check Auto PCB:s communication cable connection on the Control unit PCB
(display).
-
Change
Auto
PCB.
-
Change Control unit PCB (Display).
Filter or S-bag
indicator always or
never indicates
-
Check the bag or filter if replacement is needed.
-
Check the tubes to the pressure switches on the control unit PCB (display).
-
Change the control unit PCB (display).
Nozzle motor doesn’t
start or
stop on active system
-
Check the bent end, test with another HBTN. If possible to start nozzle
motor, change.
-
Check wiring from hose connection to 2G active PCB.
-
Change 2G active PCB, test.
-
Check wiring between 2G active PCB and control unit for failure or bad
connection.
-
Change the control unit.
LED:s on nozzle
doesn’t light,
but nozzle motor is
running
-
Change nozzle electronic