EN Publication
number
Nr
Rev. xx
Month/year
PR - 37/37
37
Cleaner with radio remote:
-
Investigate if the LED on the remote indicates transmission. If not, change
battery and try again.
-
If still no LED indication on remote, change remote control and reprogram
the cleaner according to above instruction.
-
If LED indicates transmission, try replacing the remote according to above
instruction. If cleaner starts, replace the RF remote control.
-
If still no function, replace the control unit in the cleaner. Be aware of the
position of the radio antenna. If replacing the control unit this has to learn
the RF-remote address according to above description, chapter 3.7.
Cleaner with active motor nozzle:
-
Check the bent end, test with another HBTN. If possible to change power
setting, change.
-
Check wiring from hose connection to 2G active PCB.
-
Change 2G active PCB, test.
-
Check wiring between 2G active PCB and control unit for failure or bad
connection.
-
Change the control unit.
If the power regulation works for the first minutes after start, and then stops
working. Motor seems to run only in maximum speed.
-
Check the cooling system to the Power module (tube, cooling house, tube
connection to dust compartment).
-
Change the Power module PCB.
Nozzle motor doesn’t
start or
stop on active system
-
Check the bent end, test with another HBTN. If possible to start nozzle
motor, change.
-
Check wiring from hose connection to 2G active PCB.
-
Change 2G active PCB, test.
-
Check wiring between 2G active PCB and control unit for failure or bad
connection.
-
Change the control unit.
LED’s on nozzle
doesn’t light,
but nozzle motor is
running
-
Change nozzle electronic