Adaptation to different kinds of gas
Your cooker is designed to work with natural
gas, propane or butane. It is not designed for
butane or propane air.
Connection to the LPG bottle should be car-
ried out in accordance with the enclosed pic-
ture.
The LPG conversion kit is available from your
Service Force Centre and must be fitted by
an authorised Service Engineer.
For changing the gas type it is necessary to:
• replace the nozzles (hob).
• adjust the minimum level (hob).
• check the gas connection
Warning!
Stick the label supplied with
the appliance (in the nozzles bag)
corresponding to the gas type utilised.
B
A
C
E
C
D
A) Distributor pipe
B) Nut 1/2"
C) Gasket
D) Hose nipple
E) Elbow
Hob burners nozzles
Warning!
Before replacing the nozzles
ensure that the gas knobs are in OFF
position and disconnect the appliance
from the electrical supply.
Nozzles replacement
1. Remove the pan supports.
2. Extract the caps and the wall baffles of
the burners.
3. Using a socket spanner 7 unscrew and
remove the nozzles replacing them with
the ones required for the kind of gas in
use (see table " Burner characteristics " ).
4. Reassemble the parts following the same
procedure backwards.
5. Replace the rating label (placed near the
gas supply pipe) with the relevant one for
the new type of gas supply. You can find
this label in the package of the injectors
supplied with the appliance.
These burners do not need any primary air
regulation.
Burner characteristics
CAT:2H3B/P
Burner
Normal
power
(kW)
Eco-
nomic
power
(kW)
Gas Type
Pres-
sure
(mbar)
By-
pass
(mm)
Nozzle di-
ameter
(mm)
(g/h)
Rapid
3,00
3,00
2,60
0,75
0,72
0,63
Natural gas G 20
Butan G 30
Propan G 31
20
28-30
30
0,42
1,19
0,88
0,88
-
218,14
185,68
electrolux
17