The appliance is provided with adjustable
small feet placed in the back and front cor-
ners of the base.
By adjusting the small feet it is possible to
change the height of the appliance so as to
ensure a better levelling with other surfaces
and an even distribution of the liquids con-
tained in pots and pans.
Gas connection
Gas connection must be carried out accord-
ing to the rules in force.
The manufacturing company release the unit,
once tested, adjusted for the kind of gas sta-
ted on the adjustment label located on the
back of the range, next to connection pipe.
Be sure that you are going to connect the unit
to the same kind of gas written on the label.
Otherwise, follow all the instructions of the
paragraph “Conversion of gas”.
For natural gas (G20) the working pressure is
20 mbar and for liquid gas (G30/G31) the
pressure is 30 mbar.
Connection using a rigid pipe or a flexi-
ble metal pipe
To ensure higher safety, it is recommended
to carry out the connection to the gas system
using rigid pipes (ex. copper) or using flexible
stainless steel pipes, to avoid any stress to
the unit.
Gas feeding pipe fitting is Gc1/2.
For this type of installation, connection to the
gas supply should be carried out using only
and exclusively flexible metallic tubes in con-
formity with rules in force.
Connection using flexible, non metal
pipes
When the connection can be easily inspec-
ted in its full extent, there is the chance to use
a flexible pipe according to the rules in force.
The flexible pipe should be made ready for
use in such a way that:
• nowhere it can reach overtemperature,
other than room temperature, higher than
30°C.
• it is no longer than 1500 mm.
• it shows no throttles.
• it is not subject to traction or torsion.
• it doesn’t get in touch with cutting edges
or corners.
• it can be easily inspected in order to check
its condition.
Important!
Once installation is complete,
check the perfect seal of every pipe fitting,
using a soapy solution, never a flame!
Left Hand Connection (from front)
Ensure that the rubber hose and power cord
are not in contact with any part of the hatch-
ed area shown in the diagram and that the
loop of the hose when connected is not in
contact with the floor when the appliance is
in position.
1
2
1
Rubber hose.
2
Electric cable.
Right Hand Connection (from front)
Ensure that the rubber hose and power cord
not in contact with any part of the hatched
area shown in the diagram. It will be neces-
sary to fit the maximum length hose when
using this method.
1
2
1
Rubber hose.
2
Electric cable.
16