background image

E

Installation Instructions

2

3  ElEctrIcal GroundInG 

InstructIons

This  appliance  must  be  grounded.  This  oven  is  equipped  with 
a  cord  having  a  grounding  wire  with  a  grounding  plug.  It  must 
be  plugged  into  a  wall  receptacle  that  is  properly  installed  and 
grounded  in  accordance  with  the  National  Electrical  Code  and 
local  codes  and  ordinances.  In  the  event  of  an  electrical  short 
circuit, grounding reduces risk of electric shock by providing an 
escape wire for the electric current.

WarnInG

 - Improper use of the grounding plug can result in a 

risk of electric shock.

ElEctrIcal rEquIrEMEnts

The  oven  is  equipped  with  a  3-prong  grounding  plug.  DO  NOT 
UNDER  ANY  CIRCUMSTANCES  CUT  OR  REMOVE  THE 
GROUNDING 

PIN 

FROM 

THE  PLUG.  DO  NOT  USE 
EXTENSION CORD.
The  Power  Supply  Cord  and 
plug  must  be  connected  to  a 
separate  120  Volt  AC,  60  Hz, 
15 Amp, or more branch circuit, 
single grounded receptacle. The 
receptacle  should  be  located 
inside the cabinet directly above 
the  Microwave  Oven  mounting 
location as shown in Figure 2.

notEs:

1.  If  you  have  any  questions  about  the  grounding  or  electrical 

instructions, consult a qualified electrician or serviceperson.

2.  Neither  Electrolux  nor  the  dealer  can  accept  any  liability  for 

damage to the oven or personal injury resulting from failure to 
observe the correct electrical connection procedures.

Opening for 

Power Cord

Figure 2

Ground 

Receptacle

radIo or tV IntErfErEncE

Should there be any interference caused by the microwave oven 
to your radio or TV, check that the microwave oven is on a different 
electrical circuit, relocate the radio or TV as far away from the oven 
as feasible or check position and signal of receiving antenna.

4  Hood EXHaust duct

When the hood is vented to the outside, a hood exhaust duct is 
required. All ductwork must be metal; absolutely do not use plastic 
duct. Check that all connections are made securely. Please read 
the following carefully: 

Exhaust connection:

 The hood exhaust has been designed to 

connect to a standard 3 

Z\v

" x 10" rectangular duct. If round duct is 

required, a rectangular-to-round adapter must be used.

rear exhaust:

 If a rear or horizontal exhaust is to be used, care 

should be taken to align the exhaust with the space between the 
studs,  or  wall  should  be  prepared  at  the  time  it  is  constructed 
by  leaving  enough  space  between  wall  studs  to  accommodate 
exhaust.

Maximum duct length:

 For satisfactory air movement, the total 

duct length of 3 

Z\v

" x 10" rectangular or 6" diameter round duct 

should not exceed 140 feet.
Elbows,  adapters,  wall  caps,  roof  caps,  etc.  present  additional 
resistance to air flow and are equivalent to a section of straight duct 
which is longer than their actual physical size. When calculating 
the total length, add the equivalent lengths of all transitions and 
adapters  plus  the  length  of  all  straight  duct  sections.  Figure  3 
shows the approximate feet of equivalent length of some typical 
ductwork parts. Use the values in parentheses for calculating air 
flow resistance equivalent, which should total less than 140 feet.

90˚ ELBOW (10 FT.)

45˚ ELBOW (5 FT.)

ADAPTOR (5 FT.)

90˚ ELBOW (25 FT.)

45˚ ELBOW (5 FT.)

WALL CAP (40 FT.)

ROOF CAP (24 FT.)

10" WIDE ELBOW (10 FT.)

Figure 3

5  tools rEcoMMEndEd for 

InstallatIon

•  Phillips Screwdriver
•  Electric Drill
• 

Z\₂

", 

⁵\₈

" and 

³\₃₂

" Drill Bits

•  1 

Z\₂

" Wood Bit or Metal Hole 

Cutter (if metal cabinet is 
used)

•  Saw to cut exhaust opening 

(if needed)

•  Protective Drop Cloth for 

product and range - you may 
also use carton for protection

•  Scissors
•  Pencil
•  Measure
•  Tape

Содержание EI30MH55GZ - 2.1 cu. ft. Microwave Oven

Страница 1: ... Microwave Oven should be mounted against and supported by a flat vertical wall The wall must be flat for proper installation If the wall is not flat use spacers to fill in the gaps Wall construction should be a minimum of 2 x 4 wood studding and 3 8 or more thick dry wall or plaster lath The mounting surfaces must be capable of supporting weight of 110 pounds the oven and contents AND the weight ...

Страница 2: ...k position and signal of receiving antenna 4 HOOD EXHAUST DUCT When the hood is vented to the outside a hood exhaust duct is required All ductwork must be metal absolutely do not use plastic duct Check that all connections are made securely Please read the following carefully Exhaust connection The hood exhaust has been designed to connect to a standard 3 Z v x 10 rectangular duct If round duct is...

Страница 3: ...ate Spacer 2 Grease Filter 2 Must use two may use remaining four May not use all depending on stud location Parts shown not to common scale Figure 4 7 PREPARATION OF THE OVEN 1 Turn oven on the side See Figure 5 2 Follow steps A D to remove mounting plate from the back of the oven as shown in Figure 5 A Release mounting plate by pulling out the lever that is on the bottom of the oven See Figure 6 ...

Страница 4: ... Save 2 screws to be used later and discard remaining 3 Remove Fan Cover Bracket by sliding it in the opposite direction of the arrow on the Fan Cover Bracket as shown in Figure 7 2 Lift Hood Fan Unit carefully and slip wires out of cavity See Figure 8 Caution Do not pull or stretch hood fan wiring 3 Rotate the Hood Fan Unit 180 so that the fan blade openings are facing the back of the oven See Fi...

Страница 5: ... Put the lead wire into Wire Box See Figure 13 B 4 Replace the Fan Cover Bracket by sliding it into the slits in the same direction as the arrow on the Fan Cover Bracket Make sure the fan blades are visible through the top openings in the oven before proceeding 5 Attach the Fan Cover Bracket to unit with the 2 screws from back edge and 3 screws from the top center of the Fan Cover Bracket which we...

Страница 6: ... openings on Mounting Plate Put Toggle Nuts on Toggle Bolts See Figure 17 4 Position the Mounting Plate with the Toggle Bolts attached at the wall location and insert Toggle Nuts and Bolts through the holes in the wall with the Toggle Nuts closed Figure 18 Use Wood Screws to attach the Mounting Plate to studs NOTE Before insertion be sure you leave a space more than the thickness of the wall betwe...

Страница 7: ...secure the levers that are on the bottom of the oven See Figure 21 Figure 20 Figure 21 3 Use two Top Cabinet Screws and two Flat Washers supplied in the INSTALLATION HARDWARE to attach the unit to the top cabinet See Figure 22 Figure 22 6 3 4 EXTERIOR DIMENSIONS Models EI30MH55GS GB GW 29 29 32 W x 17 1 16 H x 16 5 32 D CHECKLIST FOR INSTALLATION 1 Make sure the unit has been installed according t...

Страница 8: ......

Страница 9: ...oyarse en una pared vertical plana La pared debe ser plana para una instalación apropiada Si la pared no es plana utilice espaciadores para llenar los vacíos La construcción de pared debe consistir de montantes de madera de 2 x 4 como mínimo y tablaroca o yeso listón de 3 8 o más de espesor Las superficies de montaje deben ser capaces de soportar un peso de 50 kg 110 libras el horno y su contenido...

Страница 10: ...do el ducto debe ser metálico no utilice ducto plástico por ningún motivo Verifique que todas las conexiones se realicen de manera segura Lea detenidamente lo siguiente Conexión de escape El escape de la campana ha sido diseñado para conectarse a un ducto rectangular estándar de 3 Z v x 10 Si se requiere de un ducto redondo debe utilizarse un adaptador de rectangular a redondo Escape posterior Si ...

Страница 11: ...ro de grasa 2 Debe usar dos puede usar los cuatro restantes Puede no utilizar todos depende de la ubicación del montante Las partes mostradas no reflejan su tamaño real Figura 4 7 PREPARACIÓN DEL HORNO 1 Voltee el horno de costado Vea la Figura 5 2 Siga los pasos A D para retirar la placa de montaje de la parte posterior del horno como se muestra en la Figura 5 A Retire la placa de montaje tirando...

Страница 12: ...ilador deslizándolo en la dirección contraria de la flecha que aparece en el soporte como se muestra en la Figura 7 2 Levante la unidad de ventilador de la campana extractora y deslice los alambres afuera de la cavidad Vea la Figura 8 Precaución No jale o estire los alambres del ventilador de la campana 3 Gire la unidad de ventilador de la campana 180 para que los orificios de las paletas del vent...

Страница 13: ...mpana Coloque el conductor en la caja de alambres Vea la Figura 13 B 4 Coloque nuevamente el soporte de la cubierta del ventilador deslizándolo por las ranuras en la misma dirección de la flecha de la cubierta del ventilador Asegúrese de que las paletas del ventilador sean visibles a través de los orificios superiores en el horno antes de proceder 5 Fije el soporte de la cubierta del ventilador a ...

Страница 14: ...ros correspondientes de la placa de montaje Coloque las tuercas articuladas en los pernos acodados Vea la Figura 17 4 Coloque la placa de montaje con los pernos acodados fijados en la ubicación de pared e introduzca las tuercas articuladas y los pernos acodados en los agujeros de la pared con las tuercas articuladas cerradas Figura 18 Utilice tornillos para madera para fijar la placa de montaje a ...

Страница 15: ...ue están en la base del horno Vea la Figura 21 Figura 20 Figura 21 3 Utilice dos tornillos de gabinete superior y dos arandelas planas 6 suministradas en la TORNILLERÍA DE INSTALACIÓN para fijar la unidad al gabinete superior Vea la Figura 22 Figura 22 6 3 4 DIMENSIONES EXTERIORES Modelos EI30MH55GS GB GW 29 29 32 ancho x 17 1 16 alto x 16 5 32 profundidad LISTA DE VERIFICACIÓN PARA INSTALACIÓN 1 ...

Страница 16: ......

Страница 17: ...re supporté par un mur vertical plat Pour une installation correcte le mur doit être plat Si ce n est pas le cas employez des entretoises pour remplir les espaces La construction du mur doit avoir des poteaux muraux de 2 x 4 po et une cloison sèche ou un plâtrage d au moins 3 8 po 9 5 mm d épaisseur Les surfaces de montage doivent pouvoir supporter un poids de 110 lb 50 kg le four et son contenu E...

Страница 18: ...duit d évacuation à la hotte Tous les conduits doivent être en métal n employez aucun conduit en plastique Vérifiez que toutes les connexions sont bien serrées Veuillez lire attentivement ce qui suit Connexion de l évacuation l évacuation de la hotte est conçue pour être à un conduit rectangulaire standard de 3 1 4 x 10 po 8 3 cm x 25 4 cm Si vous avez besoin d un conduit circulaire il faut employ...

Страница 19: ...t en utiliser deux on peut utiliser les quatre restantes Peuvent ne pas être utilisées selon l emplacment du poteau Pour les armoires de métal Entoure le passage du cordon d alimentation Couper à la longeur voulue Pièces montrées à des échelles différentes Schéma 4 7 PRÉPARATION du four 1 Placer le four enappui sur un de ses côtés Voir le Schéma 5 2 Suivez les étapes A à D pour enlever la plaque d...

Страница 20: ...is qui seront réutilisées plus tard et jetez les 3 autres Enlevez cette pièce en la glissant dans la direction opposée à la flèche marquée dessus comme illustré sur le Schéma 7 2 Levez l unité de ventilation de hotte avec précaution et glissez les fils hors de la cavité voir le Schéma 8 ATTENTION Ne tirez pas sur les fils de câblage et ne les étirez pas 3 Faites pivoter le ventilateur de 180 de fa...

Страница 21: ...n Placez le fil de connexion dans la boîte de raccordement Voir le schéma 13 B 4 Remettez en place la fixation du couvercle de ventilateur en la glissant dans les fentes dans la même direction que la flèche marquée dessus Assurez vous que les pales de ventilateur sont visibles au travers des ouvertures à l arrière avant de poursuivre 5 Fixez le fixation du couverture de ventilateur à l ensemble av...

Страница 22: ...rez les boulons dans ces trous repérés de la plaque de montage Placez y de l autre côté les écrous à ailettes voir le schéma 17 4 Mettre en place la plaque de montage avec les boulons à ailettes sur l emplacement mural et insérez l extrémité des boulons avec les ailettes repliées dans les trous du mur Schéma 18 Utilisez des vis à bois pour fixer la plaque de montage par les trous portant sur le po...

Страница 23: ...s qui sont en dessous du four voir le Schéma 21 Schéma 20 Schéma 21 3 Utilisez les deux vis de l armoire supérieure et les deux rondelles plates fournies dans la QUINCAILLERIE D INSTALLATION pour fixer l unité sur l armoire supérieur Voir le schéma 22 Schéma 22 6 3 4 Dimensions extérieures EI30MH55GS GB GW 22 9 16 po L x 10 9 16 po H x 15 po P PENSE BÊTE POUR L INSTALLATION 1 Assurez vous que l ap...

Страница 24: ......

Отзывы: