Direct Electrical Connection to the Circuit 
Breaker, Fuse Box or Junction Box

If the appliance is connected directly to the circuit 
breaker, fuse box or junction box, use flexible, armored 
or nonmetallic sheathed copper cable (with grounding 
wire). Supply a U.L. listed strain-relief at each end of 
the cable. At the appliance end, the cable goes through 
the Direct Connection Hole (see Figure 5) on the Cord 
Mounting Plate. Wire sizes 

(copper wire only)

 and 

connections must conform to the rating of the appliance.

Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire 
(see Figure 5):

1.  Be sure that no power is supplied on the cable from 

residence.

2.  Remove the grounding strap from the terminal block 

and from the appliance frame.

3.  In the circuit breaker, fuse box or junction box:
  a) Connect the green (or bare copper) wire, the white 

appliance cable wire, and the neutral (white) wire 
together.

  b) Connect the 2 black wires together.
  c) Connect the 2 red wires together.

Figure 5

 3-Wire (Grounded Neutral) Electrical System 

(Example: Junction Box)

Cable from Residence

Junction

Box

White Wire

U.L.-listed Conduit 

Connector (or CSA 

listed)

Cable from 

Appliance

Green 

(or Bare Copper)

 Wire

Red

Wires

Neutral 

(white) Wire

Black

Wires

NOTE

: Be sure to remove the 

supplied grounding strap.

Where local codes DO NOT permit connecting the 
appliance-grounding conductor to the neutral 
(white) wire, or if connecting to 4-wire electrical 
system (see Figure 6):

1.  Be sure that no power is supplied on the cable from 

residence.

2.  Remove the grounding strap from the terminal block 

and from the appliance frame.

3.  In the circuit breaker, fuse box or junction box:

a) Connect the white appliance cable wire to the 

neutral (white) wire.

b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding  

wire to the grounding wire of the circuit breaker,  
fuse box or junction box.

NOTE

: Be sure to remove the 

supplied grounding strap.

U.L.-listed Conduit 

Connector (or CSA 

listed)

Figure 6 – 4-Wire Electrical System

(Example: Junction Box) 

Cable from Residence

Black

Wires

Junction

Box

White Wire

Cable from 

Appliance

Green (or Bare

Copper) Wire

Red

Wires

White Wire

Green (or Bare

Copper) Wire

Содержание EI30ES55LWB

Страница 1: ...2 Remove all packing material from the oven and the drawer compartments before connecting the electrical supply to the range 3 Observe all governing codes and ordinances 4 Be sure to leave these instructions with the consumer Important Note to the Consumer Keep these instructions with your owner s guide for future reference INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORT...

Страница 2: ...he heat generated by the range Before installing the range in an area covered with linoleum or any other synthetic floor covering make sure the floor covering can withstand heat at least 90 F 32 2 C above room temperature without shrinking warping or discoloring Do not install the range over carpeting unless you place an insulating pad or sheet of 0 64 cm thick plywood between the range and carpet...

Страница 3: ...as conduit between the range and the wall Do not seal the range to the side cabinets 24 61 cm minimum clearance between the cooktop and the bottom of the cabinet when the bottom of wood or metal cabinet is protected by not less than 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet metal 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm...

Страница 4: ... at the back and NOT by the cooktop itself Cabinet Dimensions E E E CUTOUT WIDTH Countertop and cabinet F CUTOUT DEPTH G HEIGHT OF COUNTERTOP 30 1 16 76 2 0 15 cm 21 3 4 55 2 cm Min 22 1 8 56 2 cm Max 24 61 cm Min with backguard 35 7 8 91 1 cm Min 36 5 8 93 cm Max G E min 3 8 min min 13 16 min 4 1 4 min 1 8 min 1 5 8 min Shave Raised Edge To Clear Space for 31 1 2 80 cm Wide Cooktop Rim Shaded are...

Страница 5: ...cabinet sides H1 4 front and back see illustration 1 from the floor to the top of the counter H1 H2 H3 H4 To avoid breakage Do NOT handle or manipulate the unit by the cooktop The counter top around the cut out should be flat and leveled see hatched area on illustration 1 1 2 3 5 6 7 Illustration 1 Shave Raised Edge to Clear Space for a 31 81 cm 1 Max 3 8 cm Max Wide Cooktop Illustration 2 To succ...

Страница 6: ...rounding Strap U S A Electrical Shock Hazard Electrical ground is required on this appliance Do not connect to the electrical supply until appliance is permanently grounded Disconnect power to the circuit breaker or fuse box before making the electrical connection This appliance must be connected to a grounded metallic permanent wiring system or a grounding connector should be connected to the gro...

Страница 7: ...re Copper Wire To 240 V Receptacle A User Supplied Strain relief Must Be Installed at This Location Black Wire 1 1 8 2 9cm Dia Direct Connection Hole Punch Out Knockout for 1 3 8 3 5cm Dia Cord Kit Hole NOTE Be sure to remove the supplied grounding strap Figure 4 4 Electrical Connection to the Range U S A Three Conductor Wire Connection to Range If local codes permit connection of the frame ground...

Страница 8: ...es together Figure 5 3 Wire Grounded Neutral Electrical System Example Junction Box Cable from Residence Junction Box White Wire U L listed Conduit Connector or CSA listed Cable from Appliance Green or Bare Copper Wire Red Wires Neutral white Wire Black Wires NOTE Be sure to remove the supplied grounding strap Where local codes DO NOT permit connecting the appliance grounding conductor to the neut...

Страница 9: ...your countertop If you have a square finish flat countertop no countertop preparation is required Cooktop sides lay directly on edge of countertop Formed front edged countertops must have molded edge shaved flat 3 4 1 9 cm from each front corner of opening Figure 7 Tile countertops may need trim cut back 3 4 1 9 cm from each front corner and or rounded edge flattened Figure 7 4 1 4 Cabinet Constru...

Страница 10: ...e cooktop Proper adjustments to make the top flat should be made or gaps between the countertop and the range cooktop may occur To reduce the risk of damaging your appliance do not handle or manipulate it by the cooktop Manipulate with care Position range in front of the cabinet opening Make sure that the underside of the cooktop clears the countertop If necessary raise the unit by lowering the fr...

Страница 11: ...aking or roasting Warmer Drawer some models Set the control knob to HI and check to see the drawer is heating When All Hookups are Complete Make sure all controls are left in the OFF position Before You Call for Service Read the Before you call list and operating instructions in your Use and Care Manual It may save you time and expense The list includes common occurrences that are not the result o...

Страница 12: ...the countertop Refer to Levelling the Range section 7 After installation verify that the anti tip bracket is engaged by grasping the top rear edge of the range and carefully attempt to tilt it forward to make sure range is properly anchored 8 Anti Tip Brackets Installation To reduce the risk of tipping of the range the range must be secured to the floor by properly installed anti tip bracket and s...

Отзывы: