6
FITTING THE GAS HOB
WITHOUT A COOKER HOOD ABOVE
FITTING THE GAS HOB
WITH A COOKER HOOD ABOVE
700 mm
400 mm
400 mm
100 mm
55 mm
50 mm
50 mm
600 mm
700 mm
400 mm
400 mm
100 mm
55 mm
600 mm
50 mm
50 mm
FO 2369*
FO 2231*
Important safety requirements
Location
Choose a location free of draughts and open doors and
clear of combustible materials or other fire hazards such
as curtains, etc. The location should ensure convenience
of operation and service. Any adjacent wall surface situated
within 200mm from the edge of any hob burner and above
the height of the hob must be a suitable non-combustible
material for a height of 150 mm for the entire depth and
width of the cooker.
Any combustible material above the hotplate must be at
least 650 mm above the top of the hob and no construction
shall be within 450 mm above the top of the burner.
A minimum distance of 100 mm. must be left between the
side edges of the hob and any adjacent cabinets or walls.
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
28
Semi-rapid
35
Rapid
42
Aeration adjustment none
Instructions for the Installer
Engineers technical data
Overall dimensions
Width:
685 mm.
Depth:
515 mm.
Cut Out dimensions
Width:.
560 mm.
Depth:.
480 mm.
TYPE
TYPE
NOZZLE
NOMINAL
NOMINAL
OF GAS
OF BURNER
MARKS
GAS
PRESSURE
1/100 mm CONSUMPTION
kPa
MJ/h
Rapid (large)
1.50
11.00
Semi-rapid (medium)
1.11
6.80
1.00
Auxiliary (small)
0.89
3.80
Rapid (large)
0.93
11.00
Semi-rapid (medium)
0.71
6.30
2.75
Auxiliary (small)
0.55
3.80
NATURAL
GAS
U-LPG
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V ac 50Hz supply
APPLIANCE GAS SUPPLY:
Natural gas 1.0 kPa - Universal LPG 2.75 kPa