10
Installation
Fig. 9
Installing the fume extractor hood in the wall
unit - extractor version (Filter version with
charcoal filter)
•
Apply the drilling template to the inside wall of
the wall unit on the right and left sides, and
mark out and predrill Ø 2 mm mounting holes
as well as 2 x Ø 6 mm - 5 mm depth holes for
the mounting claws (installation aids).
•
Unscrew the ventilation grill mounted on the
appliance (1 screw), apply the exhaust air union
prepared to the required exhaust air diameter,
and twist it to the right to its fullest extent (so
that it is retained).
•
Fully withdraw the vapour catcher of the hood.
•
Important: Detach and insert the grease filters
only when the vapour catcher is fully
withdrawn.
Remove the grease filters. First remove the rear
and then the front grease filter.
•
For 16 mm side walls:
Fit two spacers per side in corespondance with
fixing points.
Mount the hood with 4 x Ø 4 mm screws. Fig.
9.
•
Insert the hood in the furniture housing and
engage both mounting claws (installation aids)
on the right and left sides in the side wall of the
wall unit and firmly hold the hood for further
mounting.
Then fix the hood with the 4 x Ø 4 mm screws
supplied.
•
Refit the grease filters. Push-in the vapour
catcher.
Adjusting the extractor part (E - Fig. 1) - Fig.
10
On wall units with a body depth of 275 mm to 335
mm, the vapour catcher depth can be adjusted as
follows:
•
Remove both grease filters.
•
Loosen the screws on both end-stop brackets
and set the vapour catcher depth (min. 275 mm,
max. 335 mm).
•
Refit the screws.
•
Refit the grease filters.
Fig. 10
Содержание EFP 632
Страница 1: ...User manual EFP 936 UK ...
Страница 11: ...11 ...
Страница 12: ...LI1ZAA Ed 05 02 ...