Installation

Fig. 9

Installing the fume extractor hood in the wall
unit - extractor version (Filter version with
charcoal filter)

Apply the drilling template to the inside wall of
the wall unit on the right and left sides, and
mark out and predrill Ø 2 mm mounting holes
as well as 2 x Ø 6 mm - 5 mm depth holes for
the mounting claws (installation aids).

Unscrew the ventilation grill mounted on the
appliance (1 screw), apply the exhaust air union
prepared to the required exhaust air diameter,
and twist it to the right to its fullest extent (so
that it is retained).

Fully withdraw the vapour catcher of the hood.

Important: Detach and insert the grease filters
only when the vapour catcher is fully
withdrawn.
Remove the grease filters. First remove the rear
and then the front grease filter.

For 16 mm side walls:
Fit two spacers per side in corespondance with
fixing points.
Mount the hood with 4 x Ø 4 mm screws. Fig.
9
.

Insert the hood in the furniture housing and
engage both mounting claws (installation aids)
on the right and left sides in the side wall of the
wall unit and firmly hold the hood for further
mounting.
Then fix the hood with the 4 x Ø 4 mm screws
supplied.

Refit the grease filters. Push-in the vapour
catcher.

Adjusting the extractor part (E - Fig. 1) - Fig.
10
On wall units with a body depth of 275 mm to 335
mm, the vapour catcher depth can be adjusted as
follows:

Remove both grease filters.

Loosen the screws on both end-stop brackets
and set the vapour catcher depth (min. 275 mm,
max. 335 mm).

Refit the screws.

Refit the grease filters.

Fig. 10

Содержание EFP 632

Страница 1: ...User manual EFP 936 UK ...

Страница 2: ...Installation 8 Unpacking 8 Placement 8 Electrical connection 8 Mounting accessories included 9 Installation 10 Before you use the cooker hood we recommend that you read through the whole user manual giving a direct description of the cooker hood and its functions To avoid the risks that are always present when you use a product driven by electricity it is important that the cooker hood is installe...

Страница 3: ...ion hole a hole of 500 600 cm2 which is to say a larger hole could reduce the performance of the extractor hood If the hood is used in its filtering function it will operate simply and safely in the above conditions without the need for any of the aforementioned measures When the hood is used in its extractor function the following rules must be followed to obtain optimal operation short and strai...

Страница 4: ...ecial Accessories Extractor version In this version fumes are extracted to the outside via a hose Filter Version The air is filtered through a charcoal filter and returned to the kitchen You will need an original AEG KLF60 80 charcoal filter for the filtering function See Special Accessories Description of the Appliance 1 Motor speed switch 2 Light switch 3 Vapour catcher Extractible 4 Grease filt...

Страница 5: ...ood via the switches the set fan output is automatically re engaged If the extractor part is re inserted without operation of the switches first the blower is switched off The lighting can be separately switched on and off with the sliding switch Turn the hood on a few minutes before you start cooking then you will get an underpressure in the kitchen It should be left on after cooking for about 15...

Страница 6: ...both handles towards the centre of the hood and remove the filter pull tab W and remove central plastic strip Z to free the two filter panels Fig 3 Hand washing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Refit the grease filters when they are dry Dishwasher machine Place grease filters...

Страница 7: ...ove using the 2 red clips to retain it below press the red clips inwards and insert the charcoal filter in the holding frame Fig 4 Dismounting 1 Press both red lugs upwards towards the inside of the housing and remove the charcoal filter downwards 2 Clean the internal housing only with warm washing up liquid suds never use any abrasive cleaners brushes or scouring agents Always specify the hood mo...

Страница 8: ...nnected to any standard power socket within easy access Should it be necessary to provide a fixed connection the hood must only be installed by an electrician authorised by the local electricity board When installing an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided The manufacture declines all responsibility for malfunctions resulting from failure to com...

Страница 9: ...mm with flush mounted light screen The unobstructed internal height must be at least 370 mm Outlet hole extractor filter version When used as an extractor unit the hood must be fitted with a 120mm diameter hose Fix the flange on the hood outlet hole Bajonett attachment Fig 8a Filter version only Fix the deflector on the outlet hole of the hood Fig 8b Spice rack If a spice rack is to be incorporate...

Страница 10: ...apour catcher is fully withdrawn Remove the grease filters First remove the rear and then the front grease filter For 16 mm side walls Fit two spacers per side in corespondance with fixing points Mount the hood with 4 x Ø 4 mm screws Fig 9 Insert the hood in the furniture housing and engage both mounting claws installation aids on the right and left sides in the side wall of the wall unit and firm...

Страница 11: ...11 ...

Страница 12: ...LI1ZAA Ed 05 02 ...

Отзывы: