58
EF6
EF6: Control Reset
EF6
Checks to perform:
EF9
EF9: Hot Valve Warning
EF9
Hot and Cold Hose reversed.
Checks to perform:
WARNING
Check that all the connectors are correctly
inserted.
WARNING
Check that all the connectors are correctly
inserted.
Check wiring to main board. Unplug the unit for 1 minute and retry. If problem is not corrected replace Main
Control Board.
Troubleshooting Based on Error Codes
Check for the water supply line. Is the continuity flow
of water is there?
Y
E
S
Check if the Hot and Cold water hoses are
connecting to their respective Hot and Cold Valve?
Y
E
S
Is the temperature of Hot water same as the Cold
water?
Check for the water supply line, power
connection and repeat the diagnostic cycle to
check for any further errors.
NO
Y
E
S
Fix the Hot water in the house supply.
Switch back the Cold and Hot water hoses to
their correct position and repeat the diagnostic
cycle to check for any further errors.
NO
Check for Main Control Board and repeat the
diagnostic cycle to check for any further errors.
NO