background image

LPG conversion models EFEP916

A conversion kit is included with the product for Universal LPG usage. 
The conversion kit contains 5 or 7 injectors (refer to LPG conversion 
table) and 1 LPG sticker.
Please follow the procedure below if a conversion to suit UNIVERSAL 
LPG is required:
1.  Remove the hotplate trivets, burner caps and burner crowns to 

access the hotplate injectors. Replace the factory fitted injectors 
with the appropriate injectors, as supplied. Refer to injector orifice 
table for injector sizes. The injector size is stamped on the side of the 
injector.

2.  Unscrew the top hat nut from the regulator. The top hat nut and control 

pressure spring assembly will disengage as an assembly.

3.  Unscrew the threaded pin from top hat.
4.  Upturn threaded pin, so spring is free and screw pin back into the 

top hat until firm.

5.  Refit the top hat nut assembly to the regulator ensuring that it is 

fully screwed down. The regulator is now set for connection to LPG.

6.  Turn on the gas supply and at each new connection check for 

leaks using soapy water. Each hotplate valve should be turned 
on, one at a time, and the injector hole blanked off for several 
seconds.

7.  The operation of the regulator can be confirmed by connecting 

a manometer to the pressure test point located on the side of the 
regulator body adjacent to the outlet. 

With the appliance operating check the outlet pressure:

•  when all burners of the appliance are operating at maximum,
•  when the smallest burner of the appliance is operating at 

minimum.

Under these conditions the outlet pressure should not vary from 
the nominal outlet pressure of 2.60kPa by more than ±0.52kPa.

8.  If the regulator appears to not be performing satisfactorily then 

check the following points:

•  If the outlet pressure is consistently too low then the inlet 

pressure may be too low and adjustment of an upstream 
regulator may be needed, or an upstream regulator or valve 
with insufficient flow capacity may be present in the gas supply 
line. If this is suspected then it may be necessary to repeat the 
checks whilst measuring both the inlet and outlet pressure to 
determine if the inlet pressure is in the range  
2.75 – 7.00kPa.

•  Check that the insert has been fitted correctly.
•  Check that the turret screw is fully screwed down.
•  Check that the regulator has been fitted to the gas supply line 

in the correct orientation, the arrow on the base of the body 
indicates the direction of gas flow.

Once these checks have been completed, if the regulator still fails to 
perform in a satisfactory manner it should be replaced.

9.  One by one, turn the knobs to minimum and screw in the bypass 

screw (accessible when the knob is removed) until a small stable 
flame results. Turn the knob to maximum and then back to 
minimum to ensure that the correct minimum flame is maintained.

10. Attach the LPG sticker to the cooker, near the gas supply inlet. 

Cover the Natural Gas label that is factory fitted.

Gas pressures

The following table shows the supply and operating pressures for 
various gases.

Gas type

Natural 
gas

Universal  
LPG

Supply pressure at inlet to 
appliance regulator

1.13 (kPa)

Minimum

2.75

kPa

Operating pressure at 
appliance test point

1.00 (kPa)

2.60 kPa

The following table shows the injector sizes for  
each burner.

Injector Orifice

Natural gas

Universal LPG

Low heat burner

1.00mm

0.55mm

Medium heat burner

1.35mm

0.70mm

High heat burner

1.60mm

0.90mm

Intense heat  
dual wok burner

0.92mm 
(inner)

3 x 1.30mm 
(Outer)

0.46mm 
(inner)

3 x 0.63mm 
(outer)

Checking piping size

To work out a suitable pipe size for connection use the information in 
this table:

Model

Natural gas

Universal LPG

EFEP916

59.2 MJ/h

44.9 MJ/h

For information and requirements about construction and capacity  
of consumer piping refer to AS/NZS 5601 series of standards.

Gas connection

Read these points before connecting to the gas supply:

• 

The appliance is preset for natural gas use. If LPG is  
to be used see Conversion to LPG section.

• 

Gas installation must be made in accordance with AS/NZS 5601, 
the local gas fitting regulations, municipal codes and other 
statutory regulations.

• 

The gas connection point is a ½” BSP external thread located at 
the rear of the appliance as shown.

• 

A regulator is supplied which must be fitted to the appliance. 
Ensure that when fitted the pressure test point of regulator is 
accessible.

• 

The regulator is to be fitted to the manifold inlet at the rear of the 
appliance and the connection thread is sealed using a tape or 
jointing compound suitable for gas connections. The consumer 
piping is then connected to the inlet of the regulator, either:

directly, or

using a hose assembly and in accordance with Clause 
6.10.1.9 of AS 5601.1 (High level connection) together with 
the supplied elbow. The elbow is fitted to the inlet of 
the regulator and oriented to allow the hose to hang 
downwards. The connection thread between the regulator 
and elbow is sealed using a tape or jointing compound 
suitable for gas connections.

7

Содержание EFEP916

Страница 1: ...service agent or similarly qualified persons in order to avoid a hazard The appliance must not be installed behind a decorative door in order to avoid overheating Due to the weight 95 100kg and size of the cooker 2 persons are required to install it Gas model clearance requirements Ensure the appliance is installed in accordance with AS NZS 5601 1 or AS NZS 5202 2 while paying close attention to t...

Страница 2: ...l position Press the locking tab down for removing the door Gently close the door until it comes to a stop Then lift the door off the hinge Locking tab up at normal position Press the locking tab down for removing the door 2 Gently close the door until it comes to a stop Then lift the door off the hinge 3 Tilt and carefully lay the appliance on its back to gain access to the installation point for...

Страница 3: ... where the anti tilt brackets need to be installed 3 After the reference line is marked pull the appliance out of the cabinet cavity to install the anti tilt brackets Anti tilt bracket installation reference line WARNING Appropriate fasteners must be used to suit the type of wall on which the anti tilt brackets are installed Freestanding unit must be pushed up against the wall on installation On g...

Страница 4: ... of the appliance to prevent the product from being pulled forward when installed Measurements from the rear wall are to be adjusted if there are tiles etc that come between the appliance and the wall Once services are connected product can be lifted onto the plinth and pushed back carefully ensuring the appliance engages into both brackets at the rear and the front stops If the product requires r...

Страница 5: ... same orientation after installation Clip the kick panel onto the front feet of the appliance Make sure the kick panel snaps onto the larger section of the front feet Installing the trivets Position the 2 side trivets onto the hob first ensuring the 2 corner location recesses are to the back of the hob Position the middle trivet ensuring the trivet fingers are aligned with the side trivet fingers ...

Страница 6: ...Rated Power Input Model Total kW A1 kW A2 kW EFEP956 9 6 5 2 9 5 Power sharing between hob and oven TIPS INFORMATION IMPORTANT Before you cook in your new oven it is important that the protective oils used in the manufacture of the product be removed Make sure that the room is well ventilated to allow smoke to escape Run the grill on high for 30 minutes without grill dish Then run the oven on 220 ...

Страница 7: ...base of the body indicates the direction of gas flow Once these checks have been completed if the regulator still fails to perform in a satisfactory manner it should be replaced 9 One by one turn the knobs to minimum and screw in the bypass screw accessible when the knob is removed until a small stable flame results Turn the knob to maximum and then back to minimum to ensure that the correct minim...

Страница 8: ...s supply line in the correct orientation the arrow on the base of the body indicates the direction of gas flow Once these checks have been completed if the regulator still fails to perform in a satisfactory manner it should be replaced Testing the cooker features Observe the flame appearance on each burner If it is much smaller or larger than expected then the injector size needs checking NOTE Whe...

Отзывы: