background image

41

Control  device  for  grease  and  charcoal  filters

This hood is fitted with a device that signals when it is necessary to clean the grease filter or the charcoal filter

(if the hood is used in the recirculation version with a charcoal filter).

On delivery, the hood is not supplied with a charcoal filter, so the saturation indicator will be disabled.

If the hood is to be used with a charcoal filter, the saturation

indicator light must be enabled as follows:

Press buttons 

1-2-3

 and 

 simultaneously and hold them for 3 seconds.  At first only the grease filter

LED 

F

 will illuminate, but when the charcoal filter LED 

C

 illuminates the saturation indicator will be enabled.

To disable it: Press buttons 

1-2-3

 and 

 again simultaneously and hold

them for 3 seconds, until the charcoal filter LED 

C

 goes out.

Grease filter LED (F)

LED 

F

 will start to flash when it is time to clean the grease filter.

Cleaning will be necessary after 40 working hours.  Always comply with the maintenance instructions for the

grease filter.

Charcoal filter LED (C)

The charcoal filter LED 

C

 will start to flash when the charcoal filter needs to be replaced.

This operation is necessary after approximately 160 working hours.

Resetting  the  saturation  indicator

After cleaning or replacing the filters, press button 

 for 3 seconds until the grease filter LED 

F

 or the

charcoal filter LED 

stops flashing.

Warning!

 The resetting of the saturation indicator MUST be done in stand-by, never disconnect the hood from

the mains.

Correct  ventilation

If the cooker hood is to work correctly there must be an under pressure in the kitchen. It is important to keep the

kitchen windows closed and have a window in an adjacent room open.

Содержание EFC 9430

Страница 1: ...d Gebrauchsanweisung Installatie en gebruiksaanwijzing Notice d utilisation et d installation EFC 9430 NL D Operating and Installation Instructions Instrucciones de montaje y manejo Manual de Instruções UK F E P ...

Страница 2: ...y future owner of the appliance Safety warnings 38 For the installer 38 For the user 38 Description of the Appliance 39 Extractor version 39 Recirculation Version 39 Control Panel 40 Correct ventilation 41 Maintenance and Care 42 Cleaning the hood 42 Metal grease filter 42 Charcoal filter 43 Changing the light bulb 43 Something Not Working 44 Special accessories 44 Guarantee Conditions 45 Technica...

Страница 3: ...he extractor hood If the hood is used in its filtering function it will operate simply and safely in the above conditions without the need for any of the aforementioned measures When the hood is used in its extractor function the following rules must be followed to obtain optimal operation short and straight outlet hose keep bends in outlet hose to a minimum never install the hoses with an acute a...

Страница 4: ...tor version In this version fumes are extracted to the outside via a hose connected to the coupling ring Fig 1 In order to obtain the best performance the hose should have a diameter equal to the outlet hole Filter Version The air is filtered through a charcoal filter and returned to the kitchen You will need an original ELECTROLUX charcoal filter for the filtering function See Special Accessories...

Страница 5: ... on off The Intensive speed runs for 5 minutes If the hood is on when the Intensive speed is activated the hood will revert to previous speed after 5 minutes If the hood is off when the Intensive speed is activated the hood will automatically turn off after 5 minutes To interrupt the Intensive speed press button or The letter P appears on the display and the remaining time the point a is flashing ...

Страница 6: ...for 3 seconds until the charcoal filter LED C goes out Grease filter LED F LED F will start to flash when it is time to clean the grease filter Cleaning will be necessary after 40 working hours Always comply with the maintenance instructions for the grease filter Charcoal filter LED C The charcoal filter LED C will start to flash when the charcoal filter needs to be replaced This operation is nece...

Страница 7: ...t panel 1 and then the right 2 Proceed as follows Extract the left panel from lower side and remove it from the slot of the upper hook Fig 3 To mount proceed in the reverse manner first mounting the right 2 and then the left 1 Removing the metal grease filter Pull the handle downards then extract the filter Fig 4 Hand washing Soak grease filters for about one hour in hot water with a little washin...

Страница 8: ...eactivate the charcoal the filter should be dried in an oven for 10 minutes with a temperature of maximum 100º C After approximately three years of use the charcoal filter should be replaced with a new as the odour reduction capacity will be reduced Mounting Fig 5 Fit the charcoal filter on the rear side of the grease filter fix it with two metal wires To remove proceed in the reverse order Always...

Страница 9: ...nd outlets are not blocked The cooker hood has The safety cut out device has been tripped switched off during operation Turn off the hob and then wait for the device to reset If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damage the hood If after all these checks the problem persists contact your local Servic...

Страница 10: ...ic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the European Community EC or European Free Trade Area Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to anothe...

Страница 11: ...t for UK Safety warnings for the electrician Before connecting the appliance to the power supply check that the voltage indicated on the rating plate corresponds to the mains power supply available Appliances fitted with a plug can be connected to any standard power socket within easy access Should it be necessary to provide a fixed connection the hood must only be installed by an electrician auth...

Страница 12: ...ted on the template matches with the centre line previously marked the lower side of the template corresponds to the lower side of the hood once mounted 2 Drill two holes Ø 8mm and fix the support bracket with two wall plugs and screws 3 Remove the front panels see paragraph Removing the front panels Hang the hood 4 adjust its position 5 6 and from the inside of the hood sign two points for defini...

Страница 13: ...11 Extractor The deflector 11 Filtering version must be installed in the filtering version Attention The tall flange should be used when a telescopic chimney is required to be mounted this item should be ordered see special accessories the short flange is to be used in all other cases Remount the grease filter and the front panels 12 first the right 2 then the left 1 Connect the hood the the home ...

Страница 14: ...er of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world Electrolux 2003 ...

Отзывы: