background image

EFA 9020X air purification center (wall-mounted) with cord suspension

Installation instructions – operating instructions 

In order to utilize your exhaust hood in the best possible way, please read these instructions carefully
and keep them for later when you might need them. 

1. Safety and general information 

This   exhaust   hood  may  only  be   connected  to  a  grounded   socket   outlet   installed  according   to
regulations, or directly by a professional electrician. Fuse grounded socket outlet preferably direct
in   the   connection   box.   Electrical   data   are   found   inside   the   apparatus   on   the   type   plate   after
opening the grease collecting pan (12) behind the steel filter (15). Before opening, disconnect the
device form the mains power supply by turning off main switch (17). 

Connection and putting in operation may only be carried out by a professional electrician.

Never operate exhaust hood without filters (7/15) and/or open grease collecting pan (12). 

Always use gas cooking area appropriately. 

The flames of gas burners must always be covered by cookware.  Otherwise the exhaust hood
may become damaged due to the strong generation of heat from open gas flames. 

Before commencing any cleaning or maintenance work, the power supply to the exhaust hood
must be interrupted by unplugging the connector from the socket or by switching off main switch
(17). 

Do not prepare any flambéed dishes under the exhaust hood. The open flame could cause a fire. 

Never leave the pan unattended when you deep-fry food because the grease could catch on fire. 

Constant   maintenance   assures   unobjectionable   operation   and   maximum   performance   of   your
exhaust hood. 

All dirty surfaces should be regularly cleaned and cleared from deposits. The filter must frequently
be removed and cleaned. 

Wrong halogen lamps (13) may destroy the transformer. 

Do not cause the heat sensor to react by using a flame. 

Between ceiling and top of the hood a minimum distance of 300 mm must be observed. 

Minimum distance to the cooking range: with electric range: 700 mm, with gas stove: 700 mm. 

This   appliance   must   not   be   used   by   persons,   also   children,   with   diminished   psychological,
sensoric, or mental abilities, or by persons without any experience and knowledge unless they are
supervised   and   instructed  in  the  use   of   the  appliance  by   a  person   being  responsible  for   their
safety. 

Children must never  stay around unattended near  the appliance and in  no case  play with this
device. 

Safety shutdown: 

 

 

If one or more filters are removed, the appliance switches off automatically. The appliance is not
ready for use again before the filters are in place correctly. 

!!! Operate this appliance only with filters (7/15) inserted and grease collecting pan (12) closed !!! 

!!! Before opening this device disconnect it from the mains power supply 

by turning off main switch (17) !

Do not operate appliance without filters (7/15) 

(High voltage and UV-C radiation) 

Do not look into the lit up disinfection radiation source (14) !!!

Page 3

Содержание EFC 9020X

Страница 1: ...EFC 9020X Air purification center Wall mounted With cord suspension Installation and operating instructions Status 03 2008 ...

Страница 2: ... disc 13 Halogen lamps 20 watt EKL 5 Hanger bolt 14 Disinfection lamp UV C lamp EKL 6 Dowel 15 Stainless steel carbon filter 586 x 324 mm 7 Metal filters with ionizer sheet 16 Starter for UV C lamp with spring locking 17 Main switch 8 Cable for ionizer sheet 18 Retainer for cable suspension 9 Wall fixing rail Page 2 ...

Страница 3: ...shes under the exhaust hood The open flame could cause a fire Never leave the pan unattended when you deep fry food because the grease could catch on fire Constant maintenance assures unobjectionable operation and maximum performance of your exhaust hood All dirty surfaces should be regularly cleaned and cleared from deposits The filter must frequently be removed and cleaned Wrong halogen lamps 13...

Страница 4: ...8 mm dowels out of the by pack kit and stick them into the drilled holes 6 Take the wall fixing rail off from the rear side of the hood by unscrewing the three screws on the topside of the hood 7 Now fasten the wall fixing rail using five 5 x 50 mm round head screws from the by pack kit 8 For the cable suspension you have to copy two drill holes onto the ceiling See Sketch 2 9 Now drill the two 10...

Страница 5: ...Figure 1 Figure 2 Figure 3 Figure 4 Page 5 Sketch 1 Hole pattern for drill holes wall Sketch 2 Holes ceiling for cable suspensions ...

Страница 6: ...ainless steel filter 586 x 324 mm 15 into the hood body 1 Close grease collecting pan 12 Switch on main switch 17 on top of the device LED mains indicator is lit up green The appliance is now ready for operation UV C lamp 14 with Main switch UV C lamp 14 without protective cardboard protective cardboard Hood body 11 with Stainless steel carbon filter 15 5 Operation 7 rocker control Page 6 Heat det...

Страница 7: ...nd off separately After running Please hold the after running rocker depressed for at least 2 seconds in order to be able to assure the desired after running time 6 Exchanging halogen reflector lamps 13 Pull out defect halogen lamps 13 and press new lamps into the socket Do not pry out defect halogen lamps using metal parts e g screwdriver or knife since thereby the hood body could be damaged 7 Ta...

Страница 8: ...ry and a moist cloth Filters Caution With increasing saturation by greasy deposits flammability increases and functioning of the device may be impaired Clean metal filters 7 15 in due time Before cleaning it is imperative to remove the activated carbon attachment and knurled screws At normal operating conditions 2 to 3 hours daily the metal grease filter 7 15 needs to be cleaned every 8 to 10 week...

Страница 9: ...must be cleaned Furthermore you should check if the connector of the supply cable is connected to the ionizer sheet horizontally In case of undervoltage it can happen in power step 1 that the interconnecting relay for the ionizer and for the UVC lamp switches on and off several times flips You can eliminate this by shortly activating power step 3 Hood cannot be switched on Check if all filters are...

Страница 10: ...111 Your call will automatically be routed to your closest service location Please be at home when the service technician comes since he is dependent on your information 11 Spare parts accessories Activated carbon refill pack 1 kg A No 407 14 38 29 7 Filter cleaning agent Flamil 50 Super 200 ml A No 407 14 38 30 5 Stainless steel cleaner 200 ml A No 407 14 38 31 3 12 Quality control These devices ...

Страница 11: ...13 Warranty customer service Page 13 ...

Страница 12: ...by cleaning the upper metal filters 3 on a regular basis Using the ionizer is not hazardous Even from high dose of negative ions doesn t do you any harm A high dose of positive ions however can make you sick tired slackly sometimes even irritated and aggressive Information regarding the disinfection radiator 14 This disinfection radiator is a special low pressure mercury vapor radiator emitting sh...

Страница 13: ...ellow human beings health Environment and health are being jeopardized by incorrect disposal Additional information about the recycling of this product you will get at your city hall your garbage collection office or at the shop where you had bought this product Where to dispose of the old appliances Everywhere where new appliances are sold or delivering up at the official S EN S collection points...

Отзывы: