background image

38

      Safety warnings

For the installer

When used as an extractor unit, the hood must
be fitted with a hose having preferably the same
diameter as the outlet hole.

Attention: 

The hose is not supplied and must

be purchased separately.

When installing the hood, make sure you
observe the following minimum distance from
the top edge of the cooking hob/ring surfaces:

electric cookers

400 mm

gas cookers

650 mm

If the instructions for installation for the gas hob
specify a greater distance, this must be adhered
to.

The national Standard on fuel-burning systems
specifies a maximum depression of 0.04 mbar in
such rooms.

The air outlet must not be connected to chimney
flues or combustion gas ducts. The air outlet
must under no circumstances be connected to
ventilation ducts for rooms in which fuel-burning
appliances are installed.

The air outlet installation must comply with the
regulations laid down by the relevant local
authorities.

When the unit is used in extraction mode, a
sufficiently large ventilation hole must be
provided, with dimensions that are approxi-
mately the same as the outlet hole.

National and regional building regulations
impose a number of restrictions on using hoods
and fuel-burning appliances connected to a
chimney, such as coal or oil room-heaters and
gas fires, in the same room.

Hoods can only be used safely with appliances
connected to a chimney if the room and/or flat
(air/environment combination) is ventilated from
outside using a suitable ventilation hole approxi-
mately 500-600 cm

 large to avoid the

possibility of a depression being created during
operation of the hood.

If you have any doubts, contact the relevant
controlling authority or building inspector’s
office.

Since the rule for rooms with fuel burning
appliances is “outlet hole of the same size as the
ventilation hole”, a hole of 500-600 cm

2

, which

is to say a larger hole, could reduce the perfor-
mance of the extractor hood.

If the hood is used in its recirculation mode, it
will operate simply and safely in the above
conditions without the need for any of the
aforementioned measures.

When the hood is used in its extraction mode,
the following rules must be followed to obtain
optimal operation:
- short and straight outlet hose
- keep bends in outlet hose to a minimum
- never install the hoses with an acute angle,

they must always follow a gentle curve.

- keep the hose as large as possible (preferably

the same diameter as the outlet hole).

- the length should be no more than:

3 metres with one 90° bend
2 metres with two 90° bends
Bends of more than 90° will reduce the
efficiency of the hood and reduce the airflow.

Failure to observe these basic instructions will
drastically reduce the performance and increase
the noise levels of the extractor hood.

Содержание EFC 6400

Страница 1: ...400 NL D UK F E P Montage und Gebrauchsanweisung Installatie en gebruiksaanwijzing Notice d utilisation et d installation Operating and Installation Instructions Instrucciones de montaje y manejo Manual de Instruções ...

Страница 2: ...fety warnings 38 For the installer 38 For the user 39 Description of the Appliance 40 Extraction mode 40 Recirculation mode 40 Control Panel 41 Grease and charcoal filter maintenance indicator 41 Maintenance and Care 42 Cleaning the hood 42 Metal grease filter 42 Charcoal filter 43 Changing the light bulbs 43 Special accessories 44 What to do if 44 Technical assistance service 45 Service and Spare...

Страница 3: ...ters and gas fires in the same room Hoods can only be used safely with appliances connected to a chimney if the room and or flat air environment combination is ventilated from outside using a suitable ventilation hole approxi mately 500 600 cm2 large to avoid the possibility of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority...

Страница 4: ...d for use by young children or infirm persons without supervision Older children must be supervised if using the appliance Young children should be supervised to ensure that they do not play with the appliance WARNING Ensure that the appliance is switched off before replacing the lamp to avoid the possibility of electric shock This appliance is marked according to the European directive 2002 96 EC...

Страница 5: ...umes are extracted to the outside via a hose connected to the coupling ring A Fig 1 The connection ring is reachable opening door B hold the door with your hand when opening and closing it In order to obtain the best performance the hose should have a diameter equal to the outlet hole Recirculation mode The air is filtered through a charcoal filter and returned to the kitchen You will need an orig...

Страница 6: ...hood is not supplied with a charcoal filter so the saturation indicator will be disabled If the hood is to be used with a charcoal filter the saturation indicator light must be enabled as follows Set the hood in OFF Pressing keys 1 and 2 simultaneously for three seconds LED 3 begins to flash After 1 second the LED 4 also flashes and the system emits a sound signal Beep to indicate setting taking p...

Страница 7: ...or in the dishwasher every four weeks Removing the metal grease filter Pull the handle downwards then remove the filter Fig 3 Hand washing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Refit the grease filters when they are dry Dishwasher Place grease filters in the dishwasher Select most...

Страница 8: ...maximum temperature of 100º C After approximately three years of use the charcoal filter should be replaced with a new as the odour reduction capacity will be reduced Fitting Fig 4 Remove the frame i which supports the filter h by turning 90 the two knobs g Insert the charcoal filter inside the frame and put all parts back in their place To remove proceed in the reverse order Always specify the ho...

Страница 9: ...ood has The safety cut out device has been tripped switched off during operation Turn off the hob and then wait for the device to reset If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damage the hood If after all these checks the problem persists contact your local Service Force Centre quoting the model and se...

Страница 10: ... do if as the engineer will make a charge if the fault is not a mechanical or electrical breakdown even the appliance is under warranty Please note that proof of purchase is required for in guarantee service calls Help us to help you Please determine your type of enquiry before writing or telephoning When you contact us we need to know Your name Clear and concise details of the fault Serial number...

Страница 11: ...ic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the European Community EC or European Free Trade Area Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to anothe...

Страница 12: ... be installed by an electrician authorised by the local electricity board When installing an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided Fixed connection of the appliance must only be carried out by an authorised electrician Technical Details EFC 6400 EFC 9400 Dimensions in cm Height 65 65 Width 59 8 89 8 Depth 36 6 36 6 Maximum absorbed power 330 W 37...

Страница 13: ...1 Handle the hood with care avoiding damaging the hood commands especially when unpacking and installing Note 1 to mount the hood or access the motor housing open the door at the front hold the door with your hand when opening and closing it Fig 6 Mark the wall with a centre line this will aid mounting procedure position the template so that the mid line printed on the template matches with the ce...

Страница 14: ... drill 1 hole Ø 10mm on marked point fit 1 wall plug Hang the hood again and fix it definitively with 1 screws Fig 9 Recirculation mode Insert a section of a tube long enough to reach the outside outlet into discharge outlet A Fix the deflector with 2 screws to cover the trunk of the tube Fig 10 Extraction mode Insert a section of a tube long enough to reach outside into discharge outlet A Fig 10 ...

Страница 15: ...er of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world Electrolux 2003 ...

Отзывы: