2.3 CHECKING THE EFFICIENCY OF THE COMPONENTS
In order to facilitate the control procedure for the components to be tested, a TEST PROCEDURE has been
created which indicates the point to which the probes of the tester should be applied and the correct
theoretical value for each component tested.
Remove the door and detach all the connectors from the main board.
Connect the probes of the tester to the appropriate points on the connector. Compare the ohmic reading
with the theoretical value
.
Care should be taken relative to the position of connector “
A1
-
A2
”: f this connector is replaced
in the incorrect position (back-to-front), the appliance will not function since the power supply will
be disconnected.
Measurements points on the board wiring connectors:
LIST OF COMPONENTS
PROBE
CONTACTS
CORRECT VALUES
NOTES
L B1
0
Ω
*
) POWER CABLE &
(PU) – ON/OFF SWITCH
N A2
0
Ω
with ON/OFF button
held down
(RR) - HEATING ELEMENT
+
(TS) - SAFETY THERMOSTAT
A1 C5
25
Ω
±
8%
connected in series
(2100W)
INFINITE
on "EMPTY” (1-2)
(PR) - LEVEL PRESSURE SWITCH
B1 C5
0
Ω
on "FULL" (1-3)
INFINITE
on "EMPTY” (1-2)
(PA) - ANTI-FLOODING PRESSURE
SWITCH
C1 A2
0
Ω
on "FULL" (1-3)
(IP) - DOOR MICROSWITCH
B2 D1
0
Ω
Door closed
(DD/DB) - INTEGRATED DISPENSER
D5 D7
1.500
Ω
± 8%
OK
INFINITE
with Rinse-aid
(SB) - RINSE-AID SENSOR
F3 F4
0
Ω
without Rinse-aid
INFINITE
with salt
(SS) - SALT SENSOR
F1 F2
0
Ω
without salt
4850
Ω
± 5%
(a
25ºC)
(ST) - TEMPERATURE SENSOR
G5 G6
1205
Ω
± 5%
(a
60ºC)
(GT) - TACOMETER SENSOR
E1 E2
210
Ω
± 8%
OK
(MV) - FAN MOTOR
C11 D3
7750
Ω
± 8%
OK
(ER) - REGENERATION SOLENOID
C11 C9
6 K
Ω
± 8%
OK
(EC) - FILL SOLENOID
+
(AA) - ANTI-FLOODING DEVICE
C11 C7
3.800
Ω
± 8%
connected in series
C11 C3
50
Ω
± 8%
start-up winding
(PL) - WASH MOTOR
To the 2 motor wires
(bl) / (ro)
180
Ω
± 8%
auxiliary winding
(PS) - DRAIN MOTOR
C11 C1
180
Ω
± 8%
OK
Note: - *)
= Measurement points L and N refer to the pins of the plug fitted to the power cable.