background image

 

1  Summary table of alarms 

 

When an abnormal situation occurs that may interfere with machine functioning, the main board activates a safety system which in most cases interrupts the 

washing cycle. The last three alarm situations are stored in memory. Using a special procedure, service personnel can display all the alarms stored in memory. The user 
is only shown four of the alarms in progress. The displaying occurs by means of the no. of flashing of the “Automatic” cycle LED. 

 

Type of 

Alarm 

No. flashes 

of end-of-

cycle LED 

Displayed 

to the 

user 

Description of the alarm condition 

Machine status 

Possible causes 

i10 

yes** 

Water fill time-out 

(The pressure switch does not close on 

FULL after 90 sec. static fill, or never 
closes on “FULL” during the initial 60 

sec of the dynamic fill at 2800 rpm) 

The drain pump switches on, then 

the cycle stops. 

Tap closed; water mains pressure too low; fill 

solenoid / wiring faulty; hydraulic circuit of pressure 

switch obstructed; level pressure switch / wiring 

faulty; circuit board faulty (solenoid triac short-

circuited). 

i20 

yes** 

Water drain time-out 

(The pressure switch does not return to 

EMPTY after two drain phases lasting 

120 seconds) 

The drain pump switches on, then 

the cycle stops 

Drain circuit obstructed/blocked; drain pump 

interrupted or jammed (foreign bodies); level 

pressure switch blocked on FULL (1-3); hydraulic 

circuit of pressure switch obstructed; wiring faulty; 

circuit board faulty. 

i30 

yes** 

Intervention of Anti-flooding system 

(the drain pump switches on) 

The cycle is interrupted and the 

drain pump switches on. 

Water leakage from the tub - sump and various 

connections (pump, upper spray arm duct etc.). 

Floating sensor blocked mechanically. Microswitch 

faulty. Fill solenoid blocked mechanically. Circuit 

board faulty (solenoid triac short-circuited). Wiring 

faulty. 

i50 

yes** 

Motor triac short-circuited 

(the washing pump runs uncontrolled at 

maximum speed) 

Water fill to level (if necessary), 

deactivation of the other 

actuators, cycle interrupted. The 

washing motor runs at maximum 

speed and the alarm is displayed. 

Circuit board faulty. 

no 

Heating Time-out

  

(the check takes place every 3 minutes: 

the temperature must increase by a 

certain amount at each step) 

The programme continues to the 

end without heating (the washing 

result will probably be 

unsatisfactory). 

i60 

yes** 

Overheating: 

Temperature higher than 8°C 

The cycle is interrupted and the 

drain pump switches on. 

Heating element faulty; intervention of safety 

thermostats (open); wiring faulty; NTC sensor (poor 
thermal contact); insufficient water circulating in the 

tub; washing pump faulty (impeller stripped); circuit 

board faulty. 

 

Содержание EDW 2000 DIVA

Страница 1: ...CTS ITALY S p A Spares Operations Italy Corso Lino Zanussi 30 Publication no I 33080 PORCIA PN ITALY 599 36 92 49 Fax 39 0434 394096 Edition 2005 12 EN Dishwasher with electronic control EDW 2000 Functions DIVA 60 cm V I S I Production ZM Solaro IT ...

Страница 2: ...cle stops Drain circuit obstructed blocked drain pump interrupted or jammed foreign bodies level pressure switch blocked on FULL 1 3 hydraulic circuit of pressure switch obstructed wiring faulty circuit board faulty i30 3 yes Intervention of Anti flooding system the drain pump switches on The cycle is interrupted and the drain pump switches on Water leakage from the tub sump and various connection...

Страница 3: ...e washing pump operates at maximum speed and the alarm code is stored in memory the cycle continues Motor winding interrupted short circuited motor jammed foreign bodies wiring to washing motor faulty motor capacitor faulty Tachometric generator interrupted short circuited circuit board faulty iF0 15 no Water replenishment Time out 3 times during the T S Time out The cycle continues until the next...

Страница 4: ...2 ELECTRICAL FUNCTIONS 2 1 Electrical circuit diagram ...

Страница 5: ...spenser EC Fill solenoid ER Regeneration solenoid GA Suppressor IP Door switch MR General terminal block MV Fan motor PL Washing pump PS Drain pump PU Pushbutton array PR RL Level pressure switch PA Anti overflow pressure switch RR Heating element SB Rinse aid sensor SS Salt sensor Turbidity Turbidity sensor ST Temperature sensor TAC T Tachometric generator TS Safety thermostat Main Board Main boa...

Страница 6: ...LUES NOTES L B1 0 Ω POWER CABLE PU ON OFF SWITCH N A2 0 Ω with ON OFF button held down RR HEATING ELEMENT TS SAFETY THERMOSTAT A1 C5 25 Ω 8 connected in series 2100W INFINITE on EMPTY 1 2 PR LEVEL PRESSURE SWITCH B1 C5 0 Ω on FULL 1 3 INFINITE on EMPTY 1 2 PA ANTI FLOODING PRESSURE SWITCH C1 A2 0 Ω on FULL 1 3 IP DOOR MICROSWITCH B2 D1 0 Ω Door closed DD DB INTEGRATED DISPENSER D5 D7 1 500 Ω 8 OK ...

Страница 7: ...ash time Wash time after heating min Type of wash Heating ºC Wash time after heating min Programme time min Intensive T 55 C T 10 ctrl T 55 C T 5 T 68 C T 14 ctrl 2x3 65 C 2x T 3 ctrl 5 60 C PW1 T 69 C 105 ECO T 10 PW4 11 62 T 47 PW4 5 60 C PW1 T 4 PW4 10 69 C 160 Automatic T 8 ctrl T 50 C T 4 T 68 C T 8 ctrl T 4 PW1 5 60 C PW1 T 69 C T 1 30 100 Soak T 8 PW1 12 Notes The total time of the programm...

Страница 8: ...nents are activated i 0 i 0 i 0 4 5 6 7 8 9 10 AL 1 AL2 AL 3 ER PS EV RR PL DD MV Cancellation of alarms in memory S1 S3 S0 On Off LD1 LD2 LD3 flashing S2 All LEDs and the lamp inside the tub flash All LEDs flash for 30 sec Test cycle S1 S3 S0 On Off LD1 LD2 LD3 flashing S3 LD3 flashes Automatic LED flashes The cycle starts automatically Extra rinse S1 S3 S0 On Off LD1 LD2 LD3 flashing S1 S2 S1 LD...

Отзывы: