SOI/ADL 2009-10
33/63
599 72 40-73
ExA1
CRM_BOARD_COM_AL
CRM Satellite Board
Communication Alarm
Disables cycle execution until the communication is not restored.
Wiring Failure
Satellite Board Failure
Main Board Failure
ExA2
CRM_BOARD_PROT_INCO
NG
CRM Satellite Board
Protocol Incongruence
Alarm
Stops cycle execution.
If detected on setup, does not allow cycle start.
Software of Main Board and Satellite Board are not compatible
(Main Board or Satellite Failure)
ExA5
INPUT_BOARD_COMM_AL
Input Board
Communication Alarm
No Action
Wiring Failure
Input Board Failure
Main Board Failure
ExB1
Exh1
BAD_FREQ_AL
Power Supply Frequency
out of Range
If detected in setup, it would not be possible cycle starting. If
happens during cycle execution, it suspend working.
It is automatically cleared when power supply return within right
limits, it would be possible to start. If a cycle was temporary
suspended due to this alarm it automatically restarts.
Power Supply Problems
wrong MCF
Main Board failure
ExB2
Exh2
VOLT_TOO_HIGH_AL
Power Supply Amplitude
out of Range
(too HIGH)
Power Supply Problems - Too HIGH VOLTAGE
wrong MCF
Main Board failure
ExB3
Exh3
VOLT_TOO_LOW_AL
Power Supply Amplitude
out of Range
(too LOW)
Power Supply Problems - TOO LOW VOLTAGE
wrong MCF
Main Board failure
ExC1
MAIN_V_INCONGR_AL
Power Supply Amplitude
out of Range
No Action.
It is automatically cleared when power supply return within right
limits
Wiring Failure
Satellite Board Failure
ExC2
ZC_INCONGR_AL
Power Supply Frequency
out of Range
Wiring Failure
Satellite Board Failure
ExC3
STEAM_HEATING_TOUT
Steamer Heating-up
Timeout Alarm
No Action
Active only on diagnostic cycle. The NTC2 temperature grows too
slowly
NTC2 not well fixed.
Steamer Failure
ExC4
STEAM_HEATER_RL_FAIL
Steamer Heater Alarm
Stops cycle execution.
If detected on setup, does not allow cycle start.
Steamer Heater Disconnected (Wiring or Connector Failure,
Heater Thermal Cut-off)
Steamer Heater Failure
Steamer Heater Relay Failure (Satellite Board Failure)
ExC5
STEAM_HEATER_TERM
Steamer Heater Thermal
Cut-off Alarm
Stops cycle execution.
If detected on setup, does not allow cycle start.
ExC6
STEAM_HEATER_S_AL
Steamer Heater Sensing
Alarm
Stops cycle execution.
If detected on setup, does not allow cycle start.
Steamer Heater Sensing Circuit Failure (Satellite Board Failure)