SOI/ADL 2009-10
20/63
599 72 40-73
Position 7 ( Dryer with CONDUCTIMETRIC sensor )
Conductimetric sensor.
Drum short circuit
Purpose of test:
To verify conductimetric sensor in short circuit
condition.
Activated components:
Conductimetric sensor reading.
Behaviour:
The step lasts 4 seconds (software configured).
During this time all phase LEDs blinks to give
information of acquisition phase. At the end of
step phase LEDs are switched OFF to give ok,
otherwise a sensor alarm is generated (if sensor
alarms are enabled, otherwise phase LEDs blinks
forever).
Working conditions:
Door closed. 1 second to create the short circuit
Position 7 ( Dryer TEMPEROMETRIC sensor )
Condense Tank Switch
Purpose of test:
To test the tank switch.
Activated components:
If the pump is full of water and the tank switch
recognises the condition, the pump is switched
on.
Behaviour:
Until the condense switch is on full position,
phase LEDs blink.
When the switch goes on void position the LEDs
are switched OFF.
Working conditions:
Door closed.
Position 8 ( Dryer with CONDUCTIMETRIC sensor )
Conductimetric
sensor.
Drum open circuit
Purpose of test:
To verify conductimetric sensor in open circuit
condition.
Activated components:
Conductimetric sensor reading.
Behaviour:
The step lasts 4 seconds (software configured).
During this time all phase LEDs blinks to give
information of acquisition phase. At the end of
step phase LEDs are switched OFF to give ok,
otherwise they blink forever (no sensor alarm are
managed in this step).
Working conditions:
Door closed.
Position 8 ( Dryer TEMPEROMETRIC sensor )
Last alarm display and
Purpose of test:
To see the allarm and reset it
possible reset
Behaviour:
The LCD displays the alarm while the LED will
flash on the basis of alarm
Working conditions:
Turn the knob till position 10, paying
attention not to stop to position 7, otherwise
error 32 may occur
Position 9 ( Dryer with CONDUCTIMETRIC sensor )
Condense Tank Switch
Purpose of test:
To test the tank switch.
Activated components:
If the pump is full of water and the tank switch
recognises the condition, the pump is switched
on.