background image

1.  Never fail to have an individual power circuit specifically for the air 

conditioner. As for the method of wiring, be guided by the circuit diagram 
posted on the inside of control cover.

2.  The screw which fasten the wiring in the casing of electrical fittings are 

liable to come loose from vibrations to which the unit is subjected during 
the course of transportation. Check them and make sure that they are all 
tightly fastened. (If they are loose, it could cause burn-out of the wires.)

3.  Specification of power source.
4.  Confirm that electrical capacity is sufficient.
5.  See to that the starting voltage is maintained at more than 90 percent of the 

rated voltage marked on the name plate.

6.  Confirm that the cable thickness is as specified in the power source 

specification.

7.  Always install an earth leakage circuit breaker in a wet or moist area.
8.  The following would be caused by voltage drop. Vibration of a magnetic 

switch, which will damage the contact point, fuse breaking, disturbance of 
the normal function of the overload.

9.  The means for disconnection from a power supply shall be incorporated in 

the fixed wiring and have an air gap contact separation of at least 3mm in 
each active (phase) conductors.

Caution

After the confirmation of the above conditions, prepare the wiring as follows:

Air purging

Air and moisture in the refrigerant system have undesirable effects as 
indicated below:

1.  Pressure in the system rises.
2.  Operating current rises.
3.  Cooling or heating efficiency 

drops.

4.  Moisture in the refrigerant circuit 

may freeze and block capillary 
tubing.

5.  Water may lead to corrosion of 

parts in the refrigeration system.
6.  Therefore, the indoor unit and 

tubing between the indoor and 
outdoor unit must be leak tested 
and evacuated to remove any 
noncondensables and moisture 
from the system.

Air purging with vacuum pump

1.  Check that each tube(both liquid and gas side tubes) between the indoor 

and outdoor units have been properly connected and all wiring for the test 
run has been completed. Remove the service valve caps from both the gas 
and the liquid side on the outdoor unit. Note that both the liquid and the gas 
side service valves on the outdoor unit are kept closed at this stage.

2.  When relocate the unit to another place, perform evacuation using vacuum 

pump.

3.  Pipe length and refrigerant amount:

Caution in handling the packed valve

1.   Open the valve stem until it hits against the stopper. Do not try to open it 

further.

2.   Securely tighten the valve stem cap with a spanner or the like. Valve stem 

cap tightening torque (See Tightening torque table in page 19).

Air purging

metod

Less than 7,5 m

More than 7,5m

Additional amount of

refrigerant to be charged

Connective
pipe length

Use vacuum pump.

Use vacuum pump.

Half union

Refrigerant

A

C

D

B

Packed valve

Gas

Indoor unit

Outdoor unit

Flare nut

Stopper

Cap

Valve stem

Valve body

Liquid side:

φ

6.35mm

R22: (Pipe length-7,5)x30g/m

R410A: (Pipe length-7,5)x20g/m

Liquid side:

φ

9.52m 

R22: (Pipe length-7,5)x60g/m

R410A: (Pipe length-7,5)x40g/m

25 electrolux 

air purging

air purging 

electrolux 26

Содержание EASC12F2MBKLW

Страница 1: ...IONER 130325A S5 39 40 EM_ENGLISH MODELS EAS C E 12F2MBKLW EAS C E 18F2MBKLW ATTENTION Please read this manual completely before operating your room air conditioner MO DE SW ING SW ING TEM P SH OR TCU T FAN SPE ED TIM ER OF F RES ET LOC K TIM ER ON ...

Страница 2: ... recycling companies According to WEEE Waste of Electrical and Electronic Equipment guidelines waste from electrical and electronic devices should be collected separately If you need to dispose of this appliance in the future do NOT throw it away with the rest of your domestic garbage Instead please take the appliance to the nearest WEEE collection point where available Environmental advices Thank...

Страница 3: ...earms away It may cause fire 6 Do not operate or stop the unit by switching on or off the power It may cause electric shock or fire due to heat generation 7 Do not operate with wet hands or in damp environment It may cause electric shock 8 Do not allow water to run into electric parts It may cause failure of machine or electric shock 9 Do not drink water drained from air The air conditioner that y...

Страница 4: ...ay cause an electric shock 20 Ventilate the room well when used together with a stove etc An oxygen shortage may occur 21 When the unit is to be cleaned switch off and turn off the circuit breaker Do not clean unit when power is on as it may cause fire and electric shock it may cause an injury 22 Do not put a children pet or house plant where it will be exposed to direct air flow This could injure...

Страница 5: ...igh concentration of salinity such as coastal areas 3 Sites with sulfuric gas such as hot water springs 4 Sites with high frequency equipment such as wireless equipment welding machines and medical installations 5 Sites with flammable gases or volatile material 6 Sites with special environmental conditions 7 Laundry rooms Indoor Unit 1 The unit must be installed at a site that does not obstruct th...

Страница 6: ... least 10 meters 33 feet in length 7 The site must provide enough space around the unit as shown in the diagram 8 Children must not be able to access the installation site More than 60cm More than 30cm More than 200cm More than 30cm More than 60cm Parts list NUMBERING PART NAME Installation plate Clip anchor Self tapping screw A ST3 9x25 Seal Drain Joint QTY 1 2 3 4 5 6 1 5 8 5 8 1 1 Connecting pi...

Страница 7: ...stration is for explanation purposes only 2 Copper lines must be insulated independently 7 5 4 2 3 1 Indoor unit Outdoor unit 6 6 More than 12cm More than 12cm Air filter More than 200cm More than 60cm More than 30cm More than 60cm More than 15cm A B C 2 3m or more 11 electrolux pasts list MODE SWING SWING TEMP SHORTCUT FAN SPEED TIMER OFF RESET LOCK TIMER ON ...

Страница 8: ... drain hose into water Do not block water flow by a rise Connective pipe and drainage installation Drainage 1 Run the drain hose sloping downward Do not install the drain hose as illustrated below 2 When connecting extension drain hose insulate the connecting part of extension drain hose with a shield pipe do not let the drain hose slack Connective pipe installation 1 For the left hand and right h...

Страница 9: ...trong wind such as a seaside make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates 3 Specially in windy area install the unit to prevent the admission of wind If need suspending installation the installation bracket should accord with technique requirement in the installation bracket diagram 4 The installation wall should be solid brick...

Страница 10: ...he pipes a little longer than the measured distance D Cut the cable 1 5m longer than the pipe length 2 Burr removal A Completely remove all burrs from the cut cross section of pipe tube B Put the end of the copper tube pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing 3 Putting nut on A Remove flare nuts attached to indoor and outdoor unit then put t...

Страница 11: ...city of Max Current of the unit should be installed in power circuit 4 Ensure the air conditioner is grounded well 5 According to the attached Electrical Connection Diagram located on the panel of the outdoor unit to connect the wire 6 All wiring must comply with local and national electrical codes and be installed by qualified and skilled electricians 7 An individual branch circuit and single rec...

Страница 12: ...ectrical box cover Before performing any electrical work turn off the main power to the system 1 The inside and outside connecting cable can be connected without removing the front grille 2 The indoor power cord type is H05VV F or H05V2V2 F the outdoor power cord and interconnected cord type is H07RN F 3 Lift the indoor unit panel up remove the electrical box cover by loosening the screw 4 Ensure ...

Страница 13: ...ith the cord clamp 4 To prevent the ingress of water form a loop of the connective cable as illustrated in the installation diagram of indoor and outdoor units 5 Insulate unused cords conductors with PVC tape Process them so they do not touch any electrical or metal parts Connect the cable to the outdoor unit Terminal block of outdoor unit For 12k and 18k Btu models Screw Cover Terminal block of o...

Страница 14: ... Operating current rises 3 Cooling or heating efficiency drops 4 Moisture in the refrigerant circuit may freeze and block capillary tubing 5 Water may lead to corrosion of parts in the refrigeration system 6 Therefore the indoor unit and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any noncondensables and moisture from the system Air purging with vacuum pu...

Страница 15: ...ve stems B and A 9 Securely tighten the cap of the packed valve Electrical safety Perform the electric safe check after completing installation Gas leak check Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of th piping If bubbles come out the pipes have leakag...

Страница 16: ... weeks 5 This air conditioner was designed for use under the following conditions Optimum performance will be achieved within these operating temperatures If air conditioner is used outside of the above conditions certain safety protection features might come into operation and cause the unit to function abnormally Room relative humidity less than 80 If the air conditioner operates in excess of th...

Страница 17: ...ter It displays the room temperature when the air conditioner is in FAN only operation Displays the malfunction code or protection code Signal receiver Clean air indicator only some models Lights up when CLEAN AIR feacture is activated OPERATION indication lamp only some models This lamp illuminates when the air conditioner is in operation 1 4 2 3 Front panel frame Front panel Air filter inside fr...

Страница 18: ...ssion indicator on the remote controller fails to light 2 The remote controller is powed by two dry batteries R03 LR03X2 housed in the rear part and protected by a cover 3 Remove the cover by pressing and sliding off 4 Remove the old batteries and insert the new batteries placing the and ends correctly 5 Reattach the cover by sliding it back into position Remote control instructions Use the remote...

Страница 19: ...ling models SWING UP DOWN Used to stop or start horizontal louver movement or set the desired up down air flow direction The louver changes 6 degree in angle for each press If keep pushing more than 2 seconds the louver will swing up and down automatically SWING Used to stop or start vertical louver movement and set the desired left right air flow direction The vertical louver changes 6 degree in ...

Страница 20: ...n SET TEMP TIMER ONOFF 13 12 FAN SPEED Used to select the Fan Speed in four steps AUTO LOW MED or HIGH Each time the button is pressed the fan speed mode is shifted TIMER OFF Press this button to initiate the auto off time sequence Each press will increase the auto timed setting in 30 minutes increments When the setting time displays 10H each press will increase the auto timed setting 60 minutes i...

Страница 21: ...ller and you are not able to control the room temperature either In this case only step 1 3 and 4 may be performed Adjusting air flow direction Use the SWING UP DOWN and SWING buttons to adjust the desired airflow direction 1 When push the SWING UP DOWN button the horizontal louver changes 6 degree in angle for each push If pushing more than 2 seconds the louver will automatically swing up and dow...

Страница 22: ...ner in 6 hours 1 Press the TIMER ON button the last setting of starting operation time and the signal h will show on the display area 2 Press the TIMER ON button to display 6 0h on the TIMER ON display of the remote controller 3 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON indicator remains on and this function is activated Timer OFF Auto off operati...

Страница 23: ...R ON button 4 Press the TIMER ON button again to display 10h on the TIMER ON display 5 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON OFF indicator remains on and this function is activated TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the hou...

Страница 24: ...rection Adjust the air flow direction properly otherwise it might cause discomfort or cause uneven room temperatures Adjust the horizontal louver using the remote controller Adjust the vertical louver manually Adjusting the vertical air flow direction up down The air conditioner automatically adjusts the vertical air flow direction in accordance with the operating mode To set the horizontal air fl...

Страница 25: ...oth dampened with cold water may be used on the indoor unit if it is very dirty 4 The front panel of the indoor unit can be removed and cleaned with water Then wipe it with a dry cloth 5 Do not use a chemically treated cloth or duster to clean the unit 6 Do not use benzine thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform Cleaning the ...

Страница 26: ... to dry the inside of the unit 2 Stop the air conditioner and disconnect power Remove the batteries from the remote controller 3 The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourself Contact your dealer or servicer Checks before operation 1 Check that the wiring is not broken off or disconnected 2 Check that the air filter is installed 3 Check if the air ou...

Страница 27: ...normal condition when the air conditioner has not been used for a long time or during first use of the unit A peculiar smell comes out from the indoor unit This is caused by the indoor unit giving off smells permeated from building material from furniture or smoke The air conditioner turns to FAN only mode from COOL or HEAT For cooling and heating models only mode When indoor temperature reaches t...

Страница 28: ...ation indicator or other indicator flash 5 times per second and the flashing is not stop by disconnecting and connecting the unit 2 Frequent change of fuses and malfunctions in the switch circuit 3 Water spills over the equipment 4 Remote control does not work 5 Any other abnormal situation If your air conditioner malfunctions check the following information to find solutions or probable causes of...

Страница 29: ...Notes 55 electrolux notes notes electrolux 56 NOTES NOTES ...

Отзывы: