Electrolux EACM-09 HR/N6 Скачать руководство пользователя страница 15

Air conditioner portable 

 

15

tank is sufficient.

7.  Start and operate the recovery equipment 

according to the manufacturer's instruc-

tions

8.  Don't fill the tank to its full capacity (the liq-

uid injection volume does not exceed 80% 

of the tank volume).

9.  Even the duration is short, it must not 

exceed the maximum working pressure of 

the tank.

10. After the completion of the tank filling and 

the end of the operation process, you 

should make sure that the tanks and equip-

ment should be removed quickly and all 

closing valves in the equipment are closed.

11.  The recovered refrigerants are not allowed 

to be injected into another system before 

being purified and tested.

Note:

 Note: The identification should be made 

after the appliance is scrapped and refriger-

ants are evacuated. The identification should 

contain the date and endorsement. Make sure 

the identification on the appliance can reflect 

the flammable refrigerants contained in this 

appliance.

Recovery:

1.  The clearance of refrigerants in the system 

is required when repairing or scrapping 

the appliance. It is recommended to com-

pletely remove the refrigerant.

2.  Only a special refrigerant tank can be 

used when loading the refrigerant into the 

storage tank. Make sure the capacity of 

the tank is appropriate to the refrigerant 

injection quantity in the entire system. All 

tanks intended to be used for the recovery 

of refrigerants should have a refrigerant 

identification (i.e. refrigerant recovery tank). 

Storage tanks should be equipped with 

pressure relief valves and globe valves 

and they should be in a good condition. 

If possible, empty tanks should be evacu-

ated and maintained at room temperature 

before use.

3.  The recovery equipment should be kept in 

a good working condition and equipped 

with equipment operating instructions for 

easy access. The equipment should be 

suitable for the recovery of R290 refriger-

ants. Besides, there should be a quali-

fied weighting apparatus which can be 

normally used. The hose should be linked 

with detachable connection joint of zero 

leakage rate and be kept in a good condi-

tion. Before using the recovery equipment, 

check if it is in a good condition and if it 

gets perfect maintenance. Check if II elec-

trical components are sealed to prevent 

the leakage of the refrigerant and the fire 

caused by it. If you have any question, 

please consult the manufacturer.

4.  The recovered refrigerant shall be loaded 

in the appropriate storage tanks, attached 

with a transporting instruction, and 

returned to the refrigerant manufacturer. 

Don't mix refrigerant in recovery equip-

ment, especially a storage tank.

5.  The space loading R290 refrigeration can't 

be enclosed in the process of transporta-

tion. Take anti electrostatic measures if 

necessary in transportation. In the process 

of transport, loading and unloading, nec-

essary protective measures must be taken 

to protect the air conditioner to ensure that 

the air conditioner is not damaged.

6.  When removing the compressor or clearing 

the compressor oil, make sure the com-

pressor is pumped to an appropriate level 

to ensure that there is no residual R290 

refrigerants in the lubricating oil. The vacu-

um pumping should be carried out before 

the compressor is returned to the supplier. 

Ensure the safety when discharging oil from 

the system.

Содержание EACM-09 HR/N6

Страница 1: ...USER S MANUAL EACM 09 HR N6 EACM 12 HR N6 ...

Страница 2: ...able EACM 09 HR N6 EACM 12 HR N6 WE THINK ABOUT YOU Thank you for purchasing an Electrolux appliance You have chosen a product backed by decades of professional experience and innovations Unique and stylish it was created with care for you Therefore whenever you use it you can be sure that the results will always be excellent Welcome to Electrolux Content Safety information 3 Parts Description 4 C...

Страница 3: ... may cause harm or damage to people properties etc The seriousness is classified by the following indications WARNING This symbol indicates the possibility of death or serious injury CAUTION This symbol indicates the possibility of injury or damage to properties WARNING This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabiliti...

Страница 4: ...k fire or personal injury 1 The plug must be plugged into an outlet that is properly installed and grounded 2 Do not use an extension cord or plug adaptor with this unit CAUTION Don t apply the cold air to the body for a long time It will deteriorate your physical conditions and cause health problems Don t block air inlet or air outlet otherwise the cooling heating capacity will be weakened even c...

Страница 5: ...rol Panel TEMP indicator TEMP indicator In cooling or heating mode when or button is pressed the setting temperature is displayed and be adjusted 1 In auto cool and heat mode TEMP indica tor display is setting temperature 2 In dry and fan mode TEMP indicator dis play is room temperature Function buttons 1 button Press this button to make the unit run or stop 2 button a The running time of the unit...

Страница 6: ...G Failure to follow the below precaution could result in electrical shock fire explosion or personal injury 1 The plug must be plugged into an individual socket that is properly installed and grounded 2 Do not use an extension cord or plug adaptor with this unit Before starting the unit 1 Select a suitable location make sure the unit is near to an electrical outlet 2 Install the flexible exhaust h...

Страница 7: ...se it 2 No automatic wind sweep function models air louver minimum opening angle from air louver closed state breaking up 5 grid air louver opening angle can not be less than the minimum open angle when use it Unpacking Inspection Open the box and check unit in area with good ventilation open the door and win dow and without ignition source Note Operators are required to wear anti static devices I...

Страница 8: ...m The space shall not be less than usable space i2m2 in the specification The unit shall be installed at a well ventilated place Check the surrounding environment of installation site R290 shall not be installed in the enclosed reserved space of a build ing Installation Guide of customer The customer should have a qualified power supply coincident with that printed on the tag of the air conditione...

Страница 9: ... Screw A window slide kit Wall exhaust adaptor Adaptor B round mouth 2 Attach the window slider kit to the window sash Adjust the length of the Window Slider Kit Loose the screw A to adjust the length of the Window Slider Kit then tight the screw when the length is suitable Note the length of the Window Slider Kit is 67 5cm to 120cm Screw B 3 Carefully lower the window Secure the vent panel in pla...

Страница 10: ...efficiency As the following fig Shows Do not Yes Without installation If the unit does not have the window slider kit and wall exhaust and the Adaptor В is like this as shown in Fig H You can open the window slightly and position as shown in Fig I Fig H Fig I Water drainage During dehumidifying mode remove the upper drain plug from the back of the unit Attach the drain hose to the hole Place the o...

Страница 11: ...ouring water directly over any of the surface areas as this will cause deterioration of electrical components and wiring insulation Clean the unit When the unit is contaminated clean it gently with a wrung towel using tepid water below 40 C 104 F Clean the Air Filter 1 Remove the air filter Take out the upper air filter and the lower air filter Note There are two types about the low air intake gri...

Страница 12: ...itioner with R290 refrigerant and maintain the air conditioner in strictly accordance with manufacturer s requirements The chapter is mainly focused on special maintenance requirements for appliance with R290 refrigerant Ask repairer to read after sales technical service handbook for detailed information Qualification requirements of maintenance personnel 1 Special training additional to usual ref...

Страница 13: ... correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to installations using flammable refrigerants The charge size is in accordance with the room size within which the refrigerant con taining parts are installed The ventilation mach...

Страница 14: ... to reach the working pressure under the vacuum state then the oxygen free nitrogen is emitted to the atmosphere and in the end vacuumize the system Repeat this process until all refrigerants in the system is cleared After the final charging of the anaerobic nitrogen discharge the gas into the atmosphere pres sure and then the system can be welded This operation is necessary for welding the pipeli...

Страница 15: ... and they should be in a good condition If possible empty tanks should be evacu ated and maintained at room temperature before use 3 The recovery equipment should be kept in a good working condition and equipped with equipment operating instructions for easy access The equipment should be suitable for the recovery of R290 refriger ants Besides there should be a quali fied weighting apparatus which...

Страница 16: ...ay be considered as expendable supplies or which are made of glass The warranty is void if the defect is caused by damage ensuing by misuse poor maintenance for example a failure occurred due to ingress of foreign objects or liquids or if changes or repairs were performed by persons not authorized by the Manufacturer For the correct use of the product the user must strictly follow all included in ...

Страница 17: ...in technical and typing errors Changes to technical characteristics and assortment are subject to change without notice Mistakes and typing errors may be permitted in texts and numeric notations Product design and technical data may vary from the one pictured on the packaging Please refer to a sales consultant for more detailed information ...

Страница 18: ......

Страница 19: ...Seller Seal Date of sale Model Product Details populated upon sale Serial number ...

Страница 20: ...via Estonia and CIS countries only Electrolux is a registered trademark used under license from AB Electrolux publ This manual may contain technical and typing errors Changes to technical characteristics and assortment are subject to change without notice ...

Отзывы: