5.3
Measure against wrong electrical connection
Not provided.
5.
Technical equipment
5.1
Temperature safety device
With built-in appliances, there is a temperature fuse on the side of the air channel that switches off
the appliance in the event of overheating. The measured temperature value during a cutoff is 90°C.
Fig.: Built-in position - Temperature fuse
Notes:
-
for wiring diagram see chapter 7
-
Deviations possible with floor-mounted stoves
5.2
Fan after-running
The cooling fan switches on automatically when putting the appliance into operation. First it is in
operation to keep cool the appliance surfaces. After the oven was switched off, the fan continues
running to cool the appliance and then switches off automatically at a centre of gravity temperature
of the muffle of approx. 120°C-130°C. The post-operative ventilation is controlled via the
electronics.
Note:
-
for wiring diagram see chapter 7
-
Deviations possible with floor-mounted stoves
Содержание COOKING
Страница 32: ... 32 DGS TDS N 05 09 A B Electrolux 599 521 367 EN 7 2 Example circuit diagram OVC 1000 ...
Страница 33: ... 33 DGS TDS N 05 09 A B Electrolux 599 521 367 EN 7 3 Example circuit diagram OVC 2000 ...
Страница 34: ... 34 DGS TDS N 05 09 A B Electrolux 599 521 367 EN 7 4 Example circuit diagram SOEC ...
Страница 35: ... 35 DGS TDS N 05 09 A B Electrolux 599 521 367 EN 7 5 Example circuit diagram Prisma ...
Страница 36: ... 36 DGS TDS N 05 09 A B Electrolux 599 521 367 EN 7 6 Example circuit diagram HOC 2000 ...
Страница 37: ... 37 DGS TDS N 05 09 A B Electrolux 599 521 367 EN 7 7 Operative Equipment Overview ...
Страница 38: ... 38 DGS TDS N 05 09 A B Electrolux 599 521 367 EN Changes Pages 26 Chapter 6 1 changed ...