- 27 -
DGS-TDS-N 05.09 A. B. © Electrolux
599 521 367
EN
6.2
Measuring the temperature sensor
If a failure at the temperature sensor is assumed, the resistance can be checked by means of an
ohmmeter.
The resistance of the temperature sensor should be 500 – 600 ohms at room temperature.
Make sure to measure the insulation resistance between the metallic housing and each connection
terminal.
The resistance should be higher than 2 MOhms.
Abb. Measuring the temperature sensor