23
L
MAINTENANCE
L.1
Maintenance intervals
The inspection and maintenance intervals depend on the
actual machine operating conditions and ambient conditions
(presence of dust, damp, etc.), therefore precise time intervals
cannot be given. In any case, careful and periodical machine
maintenance is advisable in order to minimise service
interruptions.
L.1.1
Preventive Maintenance
Preventive Maintenance reduces downtime and maximizes
machines efficiency.
Customer Care Service can provide advice on the best
maintenance plan to be purchased based on the intensity of
use and the age of the equipment.
It is advisable to stipulate a preventive and scheduled
maintenance contract with the Customer Care Service.
L.2
Maintenance frequency
To ensure constant machine efficiency, it is advisable to carry
out the checks with the frequency given in the following table:
Maintenance, inspections,
checks and cleaning
Fre-
quency
Respon-
sability
Ordinary cleaning
• general cleaning of machine and
surrounding area
Daily
Operator
Ordinary cleaning
• Every month descale the wash
and rinse jets with vinegar.
Monthly
Operator
Ordinary cleaning
• Every month descale the wash
and rinse jets with scale remover.
Monthly
Service
Mechanical protection devices
• check their condition and for any
deformation, loosening or
removed parts
Monthly
Service
Control
• check the mechanical part, for
cracks or deformation, tightening
of screws: check the readability
and condition of words, stickers
and symbols and restore if
necessary
Yearly
Service
Machine structure
• Descale the boiler, inside surfa-
ces of the tank and the machine
piping.
Yearly
Service
Machine structure
• The internal hose of the rinse-aid
and detergent peristaltic dis-
penser should undergo periodic
maintenance.
Yearly
Service
Machine structure
• If present, clean the finned coil of
the energy saving device.
Yearly
Service
Machine structure
• tightening of main bolts (screws,
fixing systems, etc.) of machine
Yearly
Service
Safety signs
• check the readability and condi-
tion of safety signs
Yearly
Service
Maintenance, inspections,
checks and cleaning
Fre-
quency
Respon-
sability
Electrical control panel
• check the electrical components
installed inside the electrical con-
trol panel. Check the wiring
between the electrical panel and
machine parts.
Yearly
Service
Electrical connection cable and
plug
• check the connection cable
(replace if necessary) and plug
Yearly
Service
General machine overhaul
• check all components, electrical
equipment, corrosion, pipes…
Every
10
years
1
Service
1.
the machine is designed and built for a duration of about 10 years. After
this period of time (from commissioning) the machine must undergo a
general inspection and overhaul. Some examples of checks to be
carried out are given below.
L.3
Precautions in case of long idle periods
If the machine is not going to be used for some time, take the
following precautions:
• close the water supply tap(s);
• completely drain the tank(s);
• remove and carefully clean the filters;
• completely drain the boiler;
• remove the plug from the power socket;
• completely
drain
the
incorporated
dispenser
hoses.
Remove them from the containers;
• carefully clean the internal parts of the machine;
• clean the cabinet, going over all the stainless steel surfaces
vigorously with a rag moistened with paraffin oil to create a
protective film;
• leave the door ajar so that air can circulate inside,
preventing the formation of unpleasant odours.
• periodically air the premises.
NOTE!
After carrying out maintenance make sure the
machine is able to work safely and, in particular,
that the protection and safety devices are efficient.
L.4
Boiler drainage (only for atmospheric
versions)
If the appliance is not to be used for a long time, empty out the
boiler to prevent any malfunction and/or mildew and unpleas-
ant odours.
• Press simultaneously the buttons as shown in the figure.
• A buzzer indicates completion of drainage.
L.5
Only for models with door lock device
Checks for inspection
Содержание CLAI1G
Страница 1: ...Under Counter dishwasher EN User manual Original instructions 59566UL00 2021 03 ...
Страница 4: ...4 M TROUBLESHOOTING 24 M 1 General troubleshooting 24 M 2 Alarms 25 ...
Страница 27: ......
Страница 28: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...