background image

technical data

FEATURES

CHG642SB/WB

CHG646SB/WB

CHG956SB/WB

CHG606SB

Brand

Chef

Chef

Chef

Chef

Cooking zones

4

4

5

4

Wok

Yes

Yes

Yes

Yes

Ignition

1.5V battery

220-240V

220-240V

220-240V

Trivet

Wire Gloss

Wire Matt

Wire Matt

Wire Matt

Hob material

Stainless Steel/Enamelled 

White

Stainless Steel/Enamelled 

White

Stainless Steel/Enamelled 

White

Stainless Steel

Features

Ignition through knob

Ignition through knob

Ignition through knob

Ignition through knob

Flame safeguard

Yes

Yes

Yes

Yes

Gas Types

NG, (LP conversion kit 

supplied)

NG, (LP conversion kit 

supplied)

NG, (LP conversion kit 

supplied)

NG, (LP conversion kit 

supplied)

Cooktop dimension 

Width (mm)

600

600

860

600

Depth (mm)

535

535

510

535

Height* (mm)

55

55

51

55

Cutout dimension

Width (mm)

570

570

830

570

Depth (mm)

490

490

470

490

Energy rating (NG) 

Small burner

5.1 MJ/h

5.1 MJ/h

5.1 MJ/h

5.1 

MJ/h

Medium burner

2 x 9.0 MJ/h

2 x 9.0 MJ/h

2 x 9.0 MJ/h

9.0 

MJ/h

Large burner

12.1 MJ/h

12.1 

MJ/h

Wok burner

14.4 MJ/h

14.4 MJ/h

14.4 MJ/h

14.4 

MJ/h

Total MJ/h

37.5 MJ/h

37.5 MJ/h

49.6 MJ/h

40.6 

MJ/h

*Height is distance from the top of the kitchen bench to the bottom of the cooktop

TECHNICAL DATA  Gas Cooktops  7  

Содержание CHG606SB

Страница 1: ...GAS COOKTOPS User and Installation Manual MODELS CHG642SB WB CHG646SB WB CHG606SB CHG956SB WB SHG646SB SHG956SB WHG640SB WB WHG643SA WHG645SA WA WHG951SB WHG955SA WA ...

Страница 2: ...ur Gas Cooktop We are sure you will find your new appliance a pleasure to use and a great asset to your cooking Before you use the appliance we recommend that you read through the whole user manual which provides a description of the product and its functions To avoid the risks that are always present when you use a cooking appliance it is important that the appliance is installed correctly and th...

Страница 3: ... Only models fitted with flame safeguard can be used in marine craft caravans or mobile homes Figure 1 NOTE You must read these warnings carefully before installing or using the cooktop If you need assistance contact your Customer Care Department The manufacturer will not accept liability should the instructions below or any other safety instructions incorporated in this book be ignored Installati...

Страница 4: ...the flame can be varied by turning the control knob toward the Low position WARNING warning Keep hands clear of the burners when lighting If the burner does not light within 5 seconds turn knob to OFF position allow gas to disperse then try lighting again WARNING caution Burners MUST be operated between HIGH and LOW settings only In the absence of electrical power carry out the ignition directly t...

Страница 5: ...ushing lines WARNING caution DO NOT use abrasive scourers or steel wool Trivets burner caps and crowns These can all be lifted off and removed for separate cleaning NOTE When re fitting the burner caps and crowns ensure that they are correctly seated Ensure burners are thoroughly dried after cleaning or spillage When cleaning the burners ensure that all the flame ports are free of any blockage ref...

Страница 6: ... the burner crown refer to Figure 1 Injector is blocked Ensure injector is clear of foreign material No spark is obtained when control knob is activated Electricity supply is disconnected or switched off Switch on electricity or check fuses Battery is flat Replace battery refer to page 12 Polarity wrong on battery Reorient battery to correct position refer to page 12 Ignition electrode wet or dirt...

Страница 7: ...s Yes Yes Yes Gas Types NG LP conversion kit supplied NG LP conversion kit supplied NG LP conversion kit supplied NG LP conversion kit supplied Cooktop dimension Width mm 600 600 860 600 Depth mm 535 535 510 535 Height mm 55 55 51 55 Cutout dimension Width mm 570 570 830 570 Depth mm 490 490 470 490 Energy rating NG Small burner 5 1 MJ h 5 1 MJ h 5 1 MJ h 5 1 MJ h Medium burner 2 x 9 0 MJ h 2 x 9 ...

Страница 8: ...es Yes Gas Types NG LP conversion kit supplied NG LP conversion kit supplied NG LP conversion kit supplied Cooktop dimension Width mm 600 860 600 Depth mm 535 510 535 Height mm 55 51 55 Cutout dimension Width mm 570 830 570 Depth mm 490 470 490 Energy rating NG Small burner 5 1 MJ h 5 1 MJ h 5 1 MJ h Medium burner 2 x 9 0 MJ h 2 x 9 0 MJ h 2 x 9 0 MJ h Large burner 12 1 MJ h 12 1 MJ h Wok burner 1...

Страница 9: ...s Yes Yes Gas Types NG LP conversion kit supplied NG LP conversion kit supplied NG LP conversion kit supplied NG LP conversion kit supplied Cooktop dimension Width mm 600 600 860 860 Depth mm 535 535 510 510 Height mm 55 55 51 51 Cutout dimension Width mm 570 570 830 830 Depth mm 490 490 470 470 Energy rating NG Small burner 5 1 MJ h 5 1 MJ h 5 1 MJ h 5 1 MJ h Medium burner 9 0 MJ h 9 0 MJ h 2 x 9...

Страница 10: ...s cupboards and protection for combustible materials Ensure that the appliance is installed in accordance with clauses 6 2 5 and 6 10 1 1 of AS NZS 5601 1 or clauses 6 9 1 and 6 9 5 of AS NZS 5601 2 with regard to clearances to combustible surfaces and materials and clearances to rangehoods and exhaust fans To ensure clearances of 200mm from burners to vertical combustible surfaces observe the min...

Страница 11: ...on of gas flow when the inlet and outlet of the regulator is oriented correctly When the regulator has been fitted check for leaks from the connections with soapy water Gas connection This appliance is supplied for use with Natural Gas However it can be converted for use with LPG Refer to LP conversion on pages 13 15 Supply pipe sizing The total hourly gas consumption for the appliance is shown on...

Страница 12: ... low then the inlet pressure may be too low and adjustment of an upstream regulator may be needed or an upstream regulator or valve with insufficient flow capacity may be present in the gas supply line If this is suspected then it may be necessary to repeat the checks whilst measuring both the inlet and outlet pressure to determine if the inlet pressure is in the range 1 13 5kPa 2 Check that the r...

Страница 13: ...ng at minimum Under these conditions the outlet pressure should not vary from the nominal outlet pressure of 2 60kPa by more than 0 52kPa 8 If the regulator appears to not be performing satisfactorily then check the following points If the outlet pressure is consistently too low then the inlet pressure may be too low and adjustment of an upstream regulator may be needed or an upstream regulator or...

Страница 14: ...n the local wiring regulations Diagram 1 is a schematic of the wiring in the appliance The weight of the unit is printed on the appliance packaging label Diagram 1 Battery holder installation instructions 1 Locate a convenient position to mount battery holder keeping it away from hot surfaces WARNING warning DO NOT attach it to the base of the cooktop 2 Ensure mounting surface is clean 3 Remove pr...

Страница 15: ...d to LPG then the bypass screw will have to be screwed in until a small stable flame results Please ensure the supply pressure has been checked PRIOR to any adjustment 4 If the appliance cannot be adjusted to perform safely inform the customer of the problem and affix an appropriate warning notice to the appliance If the fault appears to be dangerous the appliance should be disconnected If a minor...

Страница 16: ...notes 16 NOTES Gas Cooktops ...

Страница 17: ...notes NOTES Gas Cooktops 17 ...

Страница 18: ...notes 18 NOTES Gas Cooktops ...

Страница 19: ...r negligent or faulty servicing or repair works done by anyone other than an Electrolux authorised repairer or ASC iv normal wear and tear v power surges electrical storm damage or incorrect power supply vi incomplete or improper installation vii incorrect improper or inappropriate operation viii insect or vermin infestation ix failure to comply with any additional instructions supplied with the A...

Страница 20: ...our Retailer phone or email our Customer Care team or visit our website Australia phone 1300 363 640 fax 1800 350 067 email customercare electrolux com au website chef com au Chef models westinghouse com au Westinghouse models New Zealand phone 0800 234 234 fax 0800 363 600 email customercare electrolux co nz website simpson co nz Simpson models westinghouse co nz Westinghouse models Top service T...

Отзывы: