background image

installation

Figure 5

110mm

115mm

wall

4. 

Fitting the cooktop into the bench.

 Carry out as follows.

•  Place the rubber seal provided around the edge of the hob.
 

NOTE: The rubber seal has talc powder applied to it’s 

surface which should be wiped off with a damp cloth 

after the unit has been installed.

Figure 6

hob

rubber seal

benchtop

screw

clamp

burner box

•  Fit the pull-down clamps supplied to ensure that the 

cooktop cannot move after installation.

WARNING

 warning

Failure to fix the cooktop to the bench could result in loosening of 

the gas connection through movement of the cooktop and a gas 

leak may result.
•  Use the 4 clamps and 4 screws supplied in the parts bag.
•  To assemble, attach the 4 clamps to each corner of the 

burner box via the screw provided.

•  When placing the cooktop in the cut-out, swing the 

clamps parallel with the box to avoid interference with the 

cut-out.

•  Position the cooktop so it is centred, then swing the 

clamps under the benchtop and tighten.

Operation on NG/SNG
Regulator

An appliance regulator is provided. The regulator must be  

positioned so that the pressure test nipple is accessible when 

the appliance is installed. Connect the gas supply to the ½” 

B.S.P. internal thread inlet of the regulator. Refer to ‘bench 

cutout’ (Figure 4) for connection point position.
Regulators are supplied pre-adjusted and configured by the 

component maker for use with Natural Gas. The appliance 

installer is not required to make an adjustment to obtain the 

correct outlet pressure setting.
An arrow on the base of the regulator indicates the direction 

of gas flow when the inlet and outlet of the regulator is 

oriented correctly. When the regulator has been fitted check 

for leaks from the connections with soapy water.

Gas connection
This appliance is supplied for use with Natural Gas. 

However, it can be converted for use with LPG. Refer to LP 

conversion on pages 13-15.

Supply pipe sizing

The total hourly gas consumption for the appliance is shown 

on the data label. The required supply pressure (i.e. at inlet 

to appliance regulator) for each gas type is shown on the 

data label, and given in Table 3. Use this information in 

conjunction with the length of run, number of elbows, tees 

and bends, the available service pressure and the supply 

requirements of other installed appliances to determine  

a suitable pipe size. For assistance in this matter refer to  

the appropriate section of AS/NZS 5601.1 or  

AS/NZS 5601.2.
An AGA certified class B or D flexible connection may be  

used to connect the cooktop in accordance with AS/NZS 

5601.1, in particular section 5.9 and clause 6.10.1.8, or 

AS/NZS 5601.2, in particular section 2.11. Where a hose 

assembly is used and the cooktop is in the installed position, 

the hose assembly shall be suitable for connection to a fixed 

consumer piping outlet located at a point 800 – 850mm 

above the floor and in the region outside the width of the 

appliance to a distance of 250mm. The point of connection 

to consumer piping must be accessible with appliance 

installed.

Elbow positioning

It is possible to reposition the elbow if required by loosening 

the locking nut and elbow by using two spanners. Re-tighten 

the entire assembly after the elbow has been repositioned. 

When fitting elbow to appliance, ensure that the sealing 

washer is fitted.

USING YOUR COOKTOP  Gas Cooktops  11  

Содержание CHG606SB

Страница 1: ...GAS COOKTOPS User and Installation Manual MODELS CHG642SB WB CHG646SB WB CHG606SB CHG956SB WB SHG646SB SHG956SB WHG640SB WB WHG643SA WHG645SA WA WHG951SB WHG955SA WA ...

Страница 2: ...ur Gas Cooktop We are sure you will find your new appliance a pleasure to use and a great asset to your cooking Before you use the appliance we recommend that you read through the whole user manual which provides a description of the product and its functions To avoid the risks that are always present when you use a cooking appliance it is important that the appliance is installed correctly and th...

Страница 3: ... Only models fitted with flame safeguard can be used in marine craft caravans or mobile homes Figure 1 NOTE You must read these warnings carefully before installing or using the cooktop If you need assistance contact your Customer Care Department The manufacturer will not accept liability should the instructions below or any other safety instructions incorporated in this book be ignored Installati...

Страница 4: ...the flame can be varied by turning the control knob toward the Low position WARNING warning Keep hands clear of the burners when lighting If the burner does not light within 5 seconds turn knob to OFF position allow gas to disperse then try lighting again WARNING caution Burners MUST be operated between HIGH and LOW settings only In the absence of electrical power carry out the ignition directly t...

Страница 5: ...ushing lines WARNING caution DO NOT use abrasive scourers or steel wool Trivets burner caps and crowns These can all be lifted off and removed for separate cleaning NOTE When re fitting the burner caps and crowns ensure that they are correctly seated Ensure burners are thoroughly dried after cleaning or spillage When cleaning the burners ensure that all the flame ports are free of any blockage ref...

Страница 6: ... the burner crown refer to Figure 1 Injector is blocked Ensure injector is clear of foreign material No spark is obtained when control knob is activated Electricity supply is disconnected or switched off Switch on electricity or check fuses Battery is flat Replace battery refer to page 12 Polarity wrong on battery Reorient battery to correct position refer to page 12 Ignition electrode wet or dirt...

Страница 7: ...s Yes Yes Yes Gas Types NG LP conversion kit supplied NG LP conversion kit supplied NG LP conversion kit supplied NG LP conversion kit supplied Cooktop dimension Width mm 600 600 860 600 Depth mm 535 535 510 535 Height mm 55 55 51 55 Cutout dimension Width mm 570 570 830 570 Depth mm 490 490 470 490 Energy rating NG Small burner 5 1 MJ h 5 1 MJ h 5 1 MJ h 5 1 MJ h Medium burner 2 x 9 0 MJ h 2 x 9 ...

Страница 8: ...es Yes Gas Types NG LP conversion kit supplied NG LP conversion kit supplied NG LP conversion kit supplied Cooktop dimension Width mm 600 860 600 Depth mm 535 510 535 Height mm 55 51 55 Cutout dimension Width mm 570 830 570 Depth mm 490 470 490 Energy rating NG Small burner 5 1 MJ h 5 1 MJ h 5 1 MJ h Medium burner 2 x 9 0 MJ h 2 x 9 0 MJ h 2 x 9 0 MJ h Large burner 12 1 MJ h 12 1 MJ h Wok burner 1...

Страница 9: ...s Yes Yes Gas Types NG LP conversion kit supplied NG LP conversion kit supplied NG LP conversion kit supplied NG LP conversion kit supplied Cooktop dimension Width mm 600 600 860 860 Depth mm 535 535 510 510 Height mm 55 55 51 51 Cutout dimension Width mm 570 570 830 830 Depth mm 490 490 470 470 Energy rating NG Small burner 5 1 MJ h 5 1 MJ h 5 1 MJ h 5 1 MJ h Medium burner 9 0 MJ h 9 0 MJ h 2 x 9...

Страница 10: ...s cupboards and protection for combustible materials Ensure that the appliance is installed in accordance with clauses 6 2 5 and 6 10 1 1 of AS NZS 5601 1 or clauses 6 9 1 and 6 9 5 of AS NZS 5601 2 with regard to clearances to combustible surfaces and materials and clearances to rangehoods and exhaust fans To ensure clearances of 200mm from burners to vertical combustible surfaces observe the min...

Страница 11: ...on of gas flow when the inlet and outlet of the regulator is oriented correctly When the regulator has been fitted check for leaks from the connections with soapy water Gas connection This appliance is supplied for use with Natural Gas However it can be converted for use with LPG Refer to LP conversion on pages 13 15 Supply pipe sizing The total hourly gas consumption for the appliance is shown on...

Страница 12: ... low then the inlet pressure may be too low and adjustment of an upstream regulator may be needed or an upstream regulator or valve with insufficient flow capacity may be present in the gas supply line If this is suspected then it may be necessary to repeat the checks whilst measuring both the inlet and outlet pressure to determine if the inlet pressure is in the range 1 13 5kPa 2 Check that the r...

Страница 13: ...ng at minimum Under these conditions the outlet pressure should not vary from the nominal outlet pressure of 2 60kPa by more than 0 52kPa 8 If the regulator appears to not be performing satisfactorily then check the following points If the outlet pressure is consistently too low then the inlet pressure may be too low and adjustment of an upstream regulator may be needed or an upstream regulator or...

Страница 14: ...n the local wiring regulations Diagram 1 is a schematic of the wiring in the appliance The weight of the unit is printed on the appliance packaging label Diagram 1 Battery holder installation instructions 1 Locate a convenient position to mount battery holder keeping it away from hot surfaces WARNING warning DO NOT attach it to the base of the cooktop 2 Ensure mounting surface is clean 3 Remove pr...

Страница 15: ...d to LPG then the bypass screw will have to be screwed in until a small stable flame results Please ensure the supply pressure has been checked PRIOR to any adjustment 4 If the appliance cannot be adjusted to perform safely inform the customer of the problem and affix an appropriate warning notice to the appliance If the fault appears to be dangerous the appliance should be disconnected If a minor...

Страница 16: ...notes 16 NOTES Gas Cooktops ...

Страница 17: ...notes NOTES Gas Cooktops 17 ...

Страница 18: ...notes 18 NOTES Gas Cooktops ...

Страница 19: ...r negligent or faulty servicing or repair works done by anyone other than an Electrolux authorised repairer or ASC iv normal wear and tear v power surges electrical storm damage or incorrect power supply vi incomplete or improper installation vii incorrect improper or inappropriate operation viii insect or vermin infestation ix failure to comply with any additional instructions supplied with the A...

Страница 20: ...our Retailer phone or email our Customer Care team or visit our website Australia phone 1300 363 640 fax 1800 350 067 email customercare electrolux com au website chef com au Chef models westinghouse com au Westinghouse models New Zealand phone 0800 234 234 fax 0800 363 600 email customercare electrolux co nz website simpson co nz Simpson models westinghouse co nz Westinghouse models Top service T...

Отзывы: