9
Instructions for converting cooktop to operate on Liquefied Petroleum Gas
IF RETURN TO NATURAL GAS SERVICE IS REQUIRED, REPEAT ALL STEPS EXCEPT USE THE
FOLLOWING TABLES TO DETERMINE THE LOCATIONS FOR THE NATURAL GAS ORIFICES AND
SHUTTER GAPS. ALL ORIFICE SHOULD HAVE BEEN SAVED FOR FUTURE USE. AGAIN SAVE THE
LPG/PROPANE ORIFICES FOR THE CASE WHERE CONVERSION IS AGAIN REQUIRED.
MODEL NUMBER: E30GC64ESS
ORIFICE AND SHUTTER DATA FOR NATURAL GAS.
ORIFICE SIZES ARE IN MILLIMETERS X 100 AND SHUTTER GAP IS IN INCHES.
Burner Position
LEFT FRONT
RIGHT FRONT
LEFT REAR
RIGHT REAR
Main Orifice
176
132
132
162
Bypass Orifice
59
54
54
57
Shutter Gap
.25
.25
.29
.34
MODEL NUMBER: E36GC65ESS
ORIFICE AND SHUTTER DATA FOR NATURAL GAS.
ORIFICE SIZES ARE IN MILLIMETERS X 100 AND SHUTTER GAP IS IN INCHES.
Burner Position
LEFT FRONT
RIGHT FRONT
CENTER
LEFT REAR
RIGHT REAR
Main Orifice
171
128
161
128
161
Bypass Orifice
60
50
54
50
54
Shutter Gap
.36
.27
.33
.36
.39
MODEL NUMBER: E46GC66ESS
ORIFICE AND SHUTTER DATA FOR NATURAL GAS.
ORIFICE SIZES ARE IN MILLIMETERS X 100 AND SHUTTER GAP IS IN INCHES.
Burner Position
LEFT FRONT
RIGHT FRONT
CENTER FRONT
LEFT REAR
RIGHT REAR
CENTER REAR
Main Orifice
176
176
130
138
125
169
Bypass Orifice
63
63
57
57
57
58
Shutter Gap
.37
.20
.27
.15
.15
.22
MODEL NUMBER: E46GC67ESS
ORIFICE AND SHUTTER DATA FOR NATURAL GAS.
ORIFICE SIZES ARE IN MILLIMETERS X 100 AND SHUTTER GAP IS IN INCHES.
Burner Position
LEFT FRONT
RIGHT FRONT
GRILL
LEFT REAR
RIGHT REAR
Main Orifice
132
175
150
165
132
Bypass Orifice
53
60
136
59
53
Shutter Gap
.14
.25
.18
.23
.24