4
Instructions for converting cooktop to operate on Liquefied Petroleum Gas
STEP 4:
REPLACE THE MAIN ORIFICES AT EACH BURNER LOCATION WITH THE ORIFICE NUMBER
LISTED IN THE TABLES ON PAGE 2. Refer to Figure 1 “ Burner Sizes and Identification” to assure the
orifice is replaced at the correct location.
AT EACH BURNER REMOVE MAIN ORIFICE USING
10mm OPEN END WRENCH HOLDING HEX OF
SHUTTTER CONNECTOR WITH ADJUSTABLE
WRENCH. DISASSEMBLED MAIN ORIFICE IS SHOWN
IN FIGURE 3.
REPLACE WITH CORRECT ORIFICE AS
DETERMINED IN STEP 2.
Note:
The shutter connector for the center Burner for
E36GC65ESS is located directly on the valve.
See figure 8 on Page 8 for the main orifice location for
the grill burner of model number E46GC67ESS.
COMPRESSION NUT
SHUTTER
CONNECTOR
ORIFICE NOZZLE NUT
BURNER TUBE
AIR SHUTTER
Figure 3
Refer to Figure 1 “ Burner Sizes and Identification” to assure the orifice is replaced at the correct
location. Save the orifices removed from the appliance for future use.
STEP 5:
SET AIR SHUTTER GAP AFTER REPLACING THE MAIN ORIFICES AT EACH BURNER
LOCATION. Refer to the Figure 1 “ Burner Sizes and Identification” to assure the SHUTTER is adjusted to
the correct gap at the correct location.
HOLD THE HEX OF THE SHUTTER CONNECTOR WITH THE
8" LONG ADJUSTABLE WRENCH AND TURN THE AIR
SHUTTER USING THE 6" LONG ADJUSTABLE WRENCH.
ROTATE SHUTTER TO ACHIEVE GAP AS LISTED FOR THE
BURNER LOCATION BEING ADJUSTED. MEASURE GAP
WITH 6" RULE UNTIL GAP IS WITHIN ±1/16 OF THE
DESIRED VALUE.
SECURE SHUTTER IN POSITION WITH LOCTITE 242 OR
EQUIVALENT.
NOTE:
USE SHUTTER MARKED WITH HN A-0053-E FOR C AND D BURNERS AND HN A-0052-E FOR
B BURNERS.
SHUTTER
CONNECTOR
ORIFICE NUT
SHUTTER
MEASURE GAP
AS SHOWN
Figure 4